Inspection History Details
Inspection Status: Correction Required
Inspection History: INSP - FOLLOW UP CODE ENFORCE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/20/2004 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | HAVE NOT HEARD FROM OWNER. PERMIT T04CM00083 CODE COMPLIANCE HAS EXPIRED. SEND CITATION. | |
| 03/26/2004 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | OWNER HAS KEPT IN CONTACT WITH INSPECTOR ON STATUS OF DRAWNGS AND PERMIT. EXTENSION GANTED 30-DAYS. F/U 4/27/04. | |
| 02/26/2004 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | COMBO PERMIT TO4CM0083 APPLIED FOR ON 1/8/04 BY OWNER DAVID BEVANS. OWNER HAS KEPT IN CONTACT WITH INSPECTOR OF DRAWINGS STATUS. MET ON SITE PER OWNERS REQUEST FOR QUESTIONS ON DRAWINGS TO BE SUBMITED. ALL MIN-HSG VIOLATIONS ABATED ON NOTICE. F/U 3/26/04. | |
| 01/30/2004 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | MET ON SITE WITH OWNER PER HIS REQUEST. FOLLOW UP INSPECTION FOUND HEAT PUMP HAS BEEN PROPERLY SERVICED. WATER HEATER ENCLOSURE LID CLEARANCE AT VENT STACK HAS BEEN CORRECTED.WATER HEATER PRESSURE RELIEF VALVE HAS BEEN EXTENDED TOWARDS THE GROUND PROPERLY. WATER DAMAGE TO SHEETROCK AT BEDROOM SOFFITT HAS BEEN PROPERLY REPAIRED AND PAINTED.INTERIOR WALL SIDING IN BEDROOM REPAIRED. FRONT EXTERIOR DOOR AND DOORJAMB PROPERLY REPAIRED TO ALLOW SAFE AND RAPID EGRESS. BOTH FRONT AND BEDROOM EXTERIOR DOORS HAVE BEEN WEATHERED PROPERLY. OWNER HAS INSTALLED REQUIRED THRESHOLD, SWEEPS AND WEATEHR STRIP TO DOORS. BROKEN WINDOW GLASS AT SOUTH LIVING ROOM WINDOW REPLACED WITH NEW. CRACKS IN LIVING ROOM EXTERIOR EAST WALLS PROPERLY PATCHED AND PAINTED. OWNER HAS APPLIED FOR NECESSARY PERMITS FOR ELECRICAL CIRCUITS AND ALTERATIONS TO GARAGE STORAGE AREA. OWNER MAKING GREAT PROGRESS ON ALL VIOLATIONS. F/U INSPECTION 3/2/04. OWNER IS CURRENTLY WORKING ON NEEDED DRAWINGS FOR SUBMITTAL TO DSD FOR PERMITS. | |
| 01/06/2004 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | MET ON SITE WITH OWNER AND TENANT. WALKED UNIT WITH OWNER ON ALL VIOLATIONS ON NOTICE. FOUND HEAT PUMP ON ROOF HAS BEEN SERVICED PROPERLY AND IN A SAFE WORKING CONDITION. EXPLAINED REPAIRS NEEDED TO FRONT ENTRY DOOR. ALL ELECTRICAL REPAIRS NECESSARY. WATER HEATER ENCLOSURE LID WHERE CLEARANCE IS NEEDED. PRESSURE RELIEF EXTENSION NEEDED. WATER DAMAGE TO BEDROOM SOFFITT AND EXTERIOR WALLS FROM WATER DAMAGE. CRACKS IN LIVING ROOM WALLS. INSPECTOR HAD DRAWINGS FROM 1964 FROM DSD RECORDS.IN WHICH A COMPARISON WAS DONE BY INSPECTOR AND OWNER. FINDING REAR UNIT WAS PERMITTED FOR A STORAGE ROOM CONVERTED INTO A LIVEABLE SPACE. INSPECTOR FINDS DRAWINGS DO NOT SHOW CONVERTED BEDROOM. IN WHICH PART OF A 3 CAR GARAGE HAS BEEN CONVERTED INTO A SLEEPING AREA. THE OWNER STATES THE PROPERTY WAS OWNED BY HIS MOTHER IN LAW AND SINCE PURCHASED BY HIM. IT HAS ALWAYS BEEN IN THIS STATE. INSPECTOR HAS INSTRUCTED OWNER A CODE COMPLIANCE PERMIT WILL BE NECESSARY FOR CONVERSION OF GARAGE INTO SLEEPING AREA TO COMPLY. ASSISTED OWNER IN PROCESS OF OBTAINING SUCH PERMITS. OWNER TO BEGIN REPAIRS TO VIOLATIONS NEXT WEEK AS PER REQUEST OF TENANT. OWNER WILL CONTACT INSPECTOR FOR A F/U INSPECTION WHEN ALL REPAIRS ARE COMPLETED. F/U 2/6/04. |