Case: T03DV01076

Parcel: 10320083D

Inspection Status: Correction Required

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
07/07/2004 INSP - INITIAL CODE ENFORCMENT Correction Required PAT MEIHROOFF FILED A MOTION TO CONTINUE AFTER MEETING WITH LAWRENCE SHUBART AND INSPECTOR CAMACHO. LAWRENCE SHUBART WILL HAVE ALEX WILSON CONTACT INSPECTOR CAMACHO AND SET UP A FOLLOW UP INSPECTION. MOTION GRANTED. NEW COURT DATE
11/06/2003 INSP - INITIAL CODE ENFORCMENT Correction Required PULLED ALL DOCUMENTS ON RECORD WITH DSD RECORDS DEPARTMENT. FOUND NO DRAWINGS OR PERMITS ON RECORD TO VERIFY ADDITIONS HAD BEEN DONE UNDER PERMIT. ALSO MET WITH YVONNE SUAREZ (CIVIL ENGINEERING ASSITANT SEWAGE SYSTEMS DIVISION PIMA COUNTY WASTE WATER DEPARTMENT). PIMA COUNTY DOES NOT HAVE ANY RECORD OR DRAWINGS TO SUPPORT ADDITIONS AND SINGLE FAMILY DWELLING HAS BEEN SPLIT INTO A DUPLEX UNDER PROPER PERMITS. SEND NOTICE.
11/05/2003 INSP - INITIAL CODE ENFORCMENT Correction Required UNIT #4
MET WITH TENANT ON SITE. FOUND:
FRONT ENTRY DOOR DOES NOT OPERATE PROPERLY IN CASE OF FIRE OR PANIC. BACKSET DOES NOT ALIGN WITH BOLT. DOOR ALSO LACKS REQUIRED WEATHER STRIP.
NO CENTRAL HEAT IN UNIT. FOUND THERMOSTAT IN HALLWAY. FURNACE IS LOCATED IN EAST SIDE APARTMENT OF DUPLEX NEXT DOOR APARTMENT # 5. TENANT DOES NOT HAVE CONTROL OVER HER OWN ENVIROMENT.
REAR EXTERIOR DOOR IN ROOM ADDITION WEATHER STRIP IS DAMAGED AT BASE OF TRIM.
ADDITION AT REAR PORCH ENCLOSED TO LIVEABLE SPACE. POSSIBLE WORK WITHOUT PERMIT. CHECK RECORDS.

UNIT #5
MET WITH TENANT ON SITE. FOUND:
FURNACE IN MECHANICAL CLOSET SERVICES BOTH UNITS. 2 SEPERATE THERMOSTATS TO FURNACE. APPLICATION IMPAIRS OPERABILITY OF FURNACE. FURNACE GAS CONNECTION PIPE NOT OF APPROVED TYPE. FLEX LINE IN USE IN PLACE OF HARD PIPE. FURNACE APPLIANCE WAS NOT PROPERLY INSTALLED OR HAS NOT BEEN MAINTAINED IN A SAFE, WORKING, OPERATING CONDITION. GAS SUPPLY SYSTEM TO FURNACE HAS NOT BEEN MAINTAINED IN A SAFE HAZARD FREE CONDITION DUE TO THE USE OF NON- APPROVED FLEX LINE IN PLACE OF REQUIRED HARD PIPE IN UNIT. BOTH PORCHES AT REAR OF UNITS HAVE BEEN ENCLOSED TO LIVEABLE SPACES. NO PERMITS ON RECORD. SMOKE DETECTOR IN BEDROOM OR HALLWAY MISSING. STAGNET WATER AT MAIN SERVICE WATER LINE AT REAR YARD AREAS. MOSQUITOS FOUND IN WATER. JAVELINA FREQUENT AREA. INTERNATIONAL PLUMBING CODE 1997 ECTION G1090102 CONNECTORS SHALL NOT BE CONCEALED WITHIN, OR EXTENDED THROUGH, WALLS, FLOORS, PARTITIONS, CEILINGS OR APPLIANCE HOUSINGS.SEND NOTICE.