Case: T03DV01000

Parcel: 126131550


Addresses:

4608 E TIMROD ST

Inspection Status: Correction Required

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
10/16/2003 INSP - INITIAL CODE ENFORCMENT Correction Required AT SITE DID INSPECTION REVIEW OF THE ELECT. HAZARDS STATED BY THE TENANT OF UNIT, I DID TRY AND MAKE CONTACT WITH TENANT AT SITE. (NO ANSWER AT DOOR). THERE WAS NO CONTACT NUMBER WITH COMPLAINT FORM. INSPECTION WAS DONE ON THE REAR ARE OF THE PROPERTY WHERE THE MAIN ELECT SYSTEM IS, THE MAIN ELECT. PANEL IS A NEW UP-GRADE, THAT WOULD SEEM TO BE DONE BY LIC. CONTRACTOR (WILL REVIEW PERMITS) UP-GRADE TO 100 AMP SYSTEM, INCLUDING RE-LOCATION OF METER AND PANEL-RISER-AFTER REVIEWING ELECT. SYSTEM I FOUND THAT THERE ARE (5) OUTSIDE LIGHTS INSTALLED ON THER EAR OF HOME AND PORCH. ALL FIVE LIGHTS ARE ON (1) LINE. FEEDING FROM WEST PORCH LIGHT COMING FROM INSIDE UNIT. THE WIRE FEEDING THE LIGHTS HAS BEEN INSTALLED WITHOUT PROPER J BOXES, CONDIT. THERE WAS FOUND THAT (2) J-BOXES ARE MISSING COVERS, THERE WAS ALSO FOUND A SPLICE IN LINE WITH WIRE CAPS AND COVERED WITH BLACK TAPE. ALSO NOTE WASHER WATER IS BEING STORED IMPROPER ALLOW WATER TO SET-UP. NOTICE WILL FOLLOW ON BARE ELECT. W/O PERMITS - WATER STORAGE PHOTO'S TAKEN AT SITE. I DID LEAVE MESSAGE WITH OWNER OF THE CURRENT ISSUE'S AT SITE AND I DID ASK TO CONTACT ME ASAP. PERMIT HAS BEEN FINALED ON ELECT. UP-GRADE ON UNIT #49115 ON JUNE 30, 1998. ALSO GAS LINE PERMIT ON JUNE 30, 1998. #44384 DSD. FILE.