Case: T03DV00879

Parcel: 107132920


Addresses:

611 E JACINTO ST


Inspection Status: Compliance

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Case Number - T03DV00879

Inspection Description - INSP - FOLLOW UP CODE ENFORCE

Inspection Status - Compliance

Date Description Inspector Results Comments
01/06/2005 INSP - FOLLOW UP CODE ENFORCE Compliance 1/06/05 VISITED SITE. OCCUPANT REFUSED INSPECTORS ENTRY,HOWEVER CONFIRMED THAT OWNER HAD INSTALLED GFCI OUTLETS IN THE KITCHEN AND BATHROOM AS REQUESTED. OWNER ALSO REMOVED ELECTRICAL AND RECEPTICLE TO THE DRYER IN PLACE OF GOING THRU PERMIT PROCESS .
CLOSED CASE PER CONFIRMATION FROM RESIDENT COMPLIANCE
12/01/2004 INSP - FOLLOW UP CODE ENFORCE Approved REVISITED SITE, KNOCKED ON DOOR, NEW RESIDENT FAWN ASWERED, MOVED IN APRIL 04, ALL ISSUES ABATED WITH EXCEPTION TO GFCI PROTECTION IN KITCHEN & BATH, NEED TO CHECK FOR PERMITS FOR 220 DRYER RECP. & LINES ADDED, TALKED W/ LEN VANCE WHO STATED THAT THOUGHT ALL THIS TIME WAS DONE, I EXPLAINED ABOUT GFCI PROTECTION AND PERMIT ISSUE FOR DRYER LINES, LEN STATED HE BOUGHT PROPERTY IN THE CONDITION THAT IT IS IN, I EXPLAINED THAT HE IS NOW OWNER AND IS RESPONSIBLE PARTY, LEN STATED HE IS THINKING ABOUT REMOVING DRYER LINES, WILL HAVE GFCI PROTECTION INSTALLED. FW/UP 30 DAYS.
04/26/2004 INSP - FOLLOW UP CODE ENFORCE Correction Required 4/26/04, REVISITED SITE, FOUND RAILINGS TO 2ND FL. HAS BEEN REPAIRED, KNOCKED ON DOOR TO UNIT NO ONE HOME, CALLED LEN VANCE MANAGEMENT COMPANY HE IS OUT OF OFFICE UNTIL NEXT MONDAY, WILL FOLLOW NEXT WEEK. F/U 5/5/04.
11/21/2003 INSP - FOLLOW UP CODE ENFORCE Correction Required 11/19/03, REVISITED SITE, DELLA WAS NOT AT HOME WHEN I ARRIVED WE DID SET AN APPT AGAIN, HAD NOTE IN DOOR WENT TO PAY PHONE BILL, WHILE ON SITE RECIEVED CALL FROM NANCY, STATING DELLA HAD CALLED HER TO SAY SHE IS ON HER WAY HOME I WAITED, UPON DOING INSP. DID FIND SOME HOUSING ISSUES, SECURITY RAILING GOING TO 2ND FLOOR IS LOOSE AND IS MISSING SECURITY BOLTS TO FLOOR, GREEN ASTRO TURF CARPERTING ON 2ND FLOOR IS DETERIORATING TO A POINT CREATING A TRIPPING HAZARD, PLYWOOD FLOOR LANDING GOING TO 2ND FLOOR IS DETERIORATING TO A POINT OF CAUSING A TRIP HAZARD, FOUND OVER FLOW TO BATH TUB MISSING ALLOWING WATER TO ENTER IN BETWEEN TUB AND WALL CAUSING DETERIORATION TO STRUCTURE, DRYWALL MISSING FROM UNDER BATH SINK FIXTURE CABINET, FRONT DOOR HAS DOUBLED KEYED DEAD BOLT INSTALLED NOT ALLOWING FOR RAPID EGRESS, BED ROOM WINDOW HAS BEEN INSTALLED ON HINGES TO OPEN INTO BEDROOM, WINDOW NOT INSTALLED ACCORDING TO MANUFACTURES RECOMMENDATIONS AND DOES NOT PROTECT FROM THE ELEMENTS, KITCHEN LIGHT FIXTURE HAS BROKEN DEFUSSURE COVER, KITCHEN CONVENIENCE OUTLETS NOT GFCI PROTECTED, WASHING MACHINE CONVENIENCE OUTLET NOT GFCI PROTECTED, ADDED ELECTRICAL 220 VOLT LINES HAS BEEN INSTALLED ON 2ND FLOOR FOR DRYER CONNENCTION, DRYER RECEPTACLE ADDED, COXIAL CABLE COVER PLATE BROKEN, REAR YARD HAS OVER GROWN WEEDS AND OLD WASHER/DRYER COMBINATION LAYING IN YARD. WOOD SLATTED FENCE GATE IS DETERIORATING TO A POINT WHERE IT DOES NOT CLOSE PROPERLY.