Inspection History Details
Inspection Status: Correction Required
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/06/2003 | INSP - INITIAL CODE ENFORCMENT | Correction Required | VISITED SITE, MET OWNER ON SITE, WALKED UNIT WITH TENANT & OWNER. MIN. HOUSING ISSUES ARE AS FOLLOWS. 1) ELECTRICAL SYSTEM IS 2 WIRE, FOUND 3 PRONG OUTLETS THROUGHOUT STRUCTURE, KITCHEN, LIVING ROOM, BATHROOM, FURNACE ROOM, ALL TESTED FOR INCORRECT CIRCUIT, BATHROOM EXHAUST FAN NOT WORKING & SMOKE DETECTOR LACKING IN STRUCTURE. 2) SW GAS HAS SHUT DOWN FURNACE & TAGGED UNIT. NOTICE OF HAZARDOUS CONDITION - HEATING APPLIANCE VENTING SYSTEM IN NEED OF REPAIR & CIRCULATING AIR (RETURN AIR) NOT SEALED AIRTIGHT FROM COMBUSTION AIR. INSPECTION & PERMIT WILL BE REQUIRED BEFORE GAS SERVICE IS REINSTATED. 3) HOT WATER HEATER LACKING T.P.R. VALVE & DRAIN & DOOR IS STICKING. GFIC MAY BE REQUIRED FOR KITCHEN SINK AREA. NO ELECTRICAL UPGRADE TO ORIGINAL SYSTEMS. 4) WINDOW IN KITCHEN CRACKED . WEATHER STRIPPING LACKING FOR FRONT DOOR. *SWITCH FOR DINING ROOM NOT WORKING PROPERLY. COOLER HAS BEEN ADDRESSED ALONG WITH SINK. CLOSET DOOR HAS FALLEN AWAY FROM DOOR CASING. WILL CHECK FOR PERMIT ON INSTALLATION OF FURNACE. 30-DAY WILL BE GIVEN TO ABATE VIOLATIONS. EXTERIOR OUTLETS LACKING WEATERHPROOF COVERS. PICTURES WERE TAKEN. |