Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Correction Required
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T03DV00672
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Correction Required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/29/2003 | INSP - INITIAL CODE ENFORCMENT | Correction Required | 7/28/03, VISITED SITE, TOOK PICTURES, MET WITH RESIDENT LA SHANDA WHO SHOWED WHERE ANTS ARE COMMING INTO HOUSE FROM EXTERIOR, ALSO SHOWED WHERE IS IS USING CANS OF RAID TO TRY TO KEEP THEM AT BAY, DID SEE ACTIVITY OF ANTS OUTSIDE OF UNIT, ALSO SAW SOME ANTS INSIDE, MOST OF WEATHER PROTECTION AROUND DOOR IS GOOD BUT THERE IS A SMALL GAP AT LEFT SIDE BOTTOM SHOWING LIGHT AND COULD ALLOW ENTRY, ALSO MAIN WATER SUPPLY VALVE MISSING HANDLE TO TURN OFF IN CASE OF EMERGENCY, KITCHEN WINDOW HAS CRACK IN IT, NO OTHER ISSUES IN UNIT AT THIS TIME, FLOURESENTS LIGHTS IN LAUNDRY ROOM ARE EXPOSED AND UNPROTECTED. N.O. TO FOLLOW. F/U 30 DAYS 8/29/03 |