Inspection History Details
Inspection Status: Correction Required
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/22/2007 | INSP - INITIAL CODE ENFORCMENT | Correction Required | 1/17/07 RESTARTED CASE: PROSECUTOR VISITED SITE, MET WITH OCCUPANT MARIA, EXPLAINED THAT I HAVE AN OPEN CASE ON SITE, AND THAT WHEN I MET WITH PROSECUTOR IT WAS SUGGESTED THAT I COMPLETELY START OVER AGAIN. FRONT ENTRY DOOR CRACKED ON DOOR PANELS, BEING SEALED BY DUCT TAPE, FRONT DOOR LACKS WEATHER PROTECTION. FRONT DOOR JAMB BROKEN. LIVING ROOM WINDOW BROKEN. L/R EAST CONVENIENCE OUTLET MISSING PROTECTIVE COVER PLATE. SAME CONVENIENCE OUTLET SHOWS OPEN GROUND UNDER TEST. HOLE IN WALL. LIVING ROOM LACKS REQUIRED SMOKE DET. FLOOR TILE AROUND FRONT DOOR BROKEN CHIPPED AND MISSING IN AREAS. LIVING ROOM CEILING SHOWS EVIDENCE OF LEAKING INTO LIVING SPACE. LIVING ROOM LIGHT FIXTURE NOT SECURED, HANGING BY ELECTRICAL WIRES. ELECTRICAL PROTECTIVE COVER PLATES MISSING THROUGHT OUT DWELLING. LIVING ROOM WALL PLASTER CRACKED. LIVING ROOM WEST WALL WINDOW DOES NOT FIT PROPERLY INTO WINDOW FRAME, OPENINGS, DOES NOT PRTOPERLY SEAL. OCCUPANT USING SPACE HEATERS THROUGH OUT ALL ROOMS FOR HEAT. STATES PERMANENT SOURCE OF HEAT DOES NOT OPERATE. 90% OF KITCHEN FLOOR MISSING TILE. KITCHEN FLOOR CRACKED AND HAS A LIP FROM SETTELING. KITCHEN DOOR LACKS WEATHER PROTECTION. DOOR CRACKED, HOLE SEALED WITH PLASTIC BAG STUFFED INTO CRACK. RANGE HOOD FOR COOK STOVE USING ZIP WIRE TO SUPPLY ELECTRIC. KITCHEN FAUCET LEAKS AT HANDLE. KITCHEN LIGHT FIXTURE MISSING PROTECTIVE COVBER. NORTH/EAST BEDROOM LIGHT SWITCH MISSING PROTECTIVE COVER PLATE. CONVENIENCE OUTLET BROKEN, SOUTH WALL. BEDROOM EAST WALL WINDOW HAS BEEN REPLACED FROM ORIGINAL, REPLACEMENT TO SMALL FOR EGRESS, WINDOW LOCATED ON NORTH WALL HAS WROUGHT IRON SECURITY BARS, NOT QUICK RELEASE FOR EGRESS. NORTH WALL PLASTER CRACKED. CLOSET WALL CRACKED. USING SPACE HEATER FOR HEAT. BEDROOM DOOR HANDLE BROKEN. BEDROOM DOOR BROKEN. BATHROOM DOOR JAMB BROKEN. BATHROOM DOOR JAMB MOULDING BROKEN, DOOR WILL NOT SECURE AS INTENDED. BATHROOM LIGHT FIXTURE MISSING PROTECTIVE COVER. BATHROOM SINK LEAKS UNDERNEITH. BOTTOM OF BATH VANITY DETERIORATED DUE TO LEAK ALSO EAST SIDE OF VANITY CABINET. REPLACEMENT OF WATER LINES TO BATHROOM SINK FIXTURE, AND TOILET. SHOWER WALL PROTECTIVE COVERING DETERIORATING ALLOWS FOR WATER TO ENTER IN BEHIND AND DETERIORATE STRUCTURE. SHOWER/TUB OVER FLOW CAP NOT INSTALLED PROPERLY. BEDROOM SOUTH/EAST USING SPACE HEATER FOR HEAT. EAST WALL WINDOW HAS BEEN REPLACED, TO TO SMALL, DOES NOT MEET EGRESS REQUIREMENTS. WINDOW ALSO DOES NOT SEAL PROPERLY FROM EXTERIOR ELEMENTS. CONVENIENCE OUTLET COVER PLATE BROKEN. ELECTRICAL SUB-PANEL DEAD PLATE NOT PROPERLY SECURED. INTERIOR SHOWS DOUBLE LUGGING. PERMANENT SOURCE OF HEAT NOT BEING UTILIZED, DIRTY, PILOT LIGHT NOT WORKING, NOT LITE. EXTERIOR: WOOD EAVES, DOORS, DETERIORATING LACK OF PROTECTIVE COVERING (PAINT). DOORS ARE CRACKED SPLITTING DOES NOT PROTECT FORM EXTERIOR ELEMENTS. WASHER: UTILIZING ELECT FROM EXTENSION CORD THROUGH KITCHEN WINDOW. DRAIN LINE CONNECTED INTO ADDED SEWER LINE FROM KITCHEN SINK THIS SEWER LINE IS NOT INSTALLED PROPERLY. AND EXPOSED TO EXTERIOR ELEMENTS. ELECTRICAL SERVICE PANEL MISSING BREAKER PLUG CAP. WATER HEATER METAL CABINET NOT PROPERLY SECURED, DOOR BENT UP DOES NOT STAY IN PLACE. GAS EXHAUST FLUE PIPE MISSING CAP. GAS EXHAUST FLUE PIPE DOES NOT EXTEND PAST COOLER, TO CLOSE. UNIT A SHOWS WORK BEING DONE TO WATER LINES NO PERMIT SECURED IN PERMIT PLUS. NEW STRUCTURE STILL IN REAR OF PROPERTY SITS ON PROPERTY LINE, NO PERMITS IN PERMITS PLUS FOR COMPLETE STRUCTURE. |
|
| 07/23/2003 | INSP - INITIAL CODE ENFORCMENT | Correction Required | 7/9/03, VISITED SITE, TOOK PICTURES, MET WITH RESIDENT WHO SHOWED WHERE ROOF LEAKS WHEN IT RAINS, ALSO RESIDENT IS USING ALTERNATIVE METHOD OF COOLING, HAS 2 PORTABLE WINDOW A/C UNITS ONE IN EACH BEDROOM, THESE ARE PLUGED INTO CONVENIENCE OUTLETS, PERMANATE COOLING (COOLER) DOES NOT WORK, ALSO FOUND THAT IN B/R # 2 ELECTRICAL CONVENIENCE OUTLETS SOME DO NOT WORK AT ALL SHOWS NO POWER UNDER TEST, ALSO B/R # 2 DOOR HANDLE MISSING, THERE IS HOLE IN DRYWALL ABOVE WALL HEATER, TILE MISSING ON FLOOR AT HALLWAY GOING TO L/R, VYNIL COMMING UP FROM BATH ROOM FLOOR AROUND TOILET, AND BATH SINK FIXTURE LOOSE FROM VANITY COUNTER TOP, MARLITE CRACKED IN TUB AND SHOWER AREA, ALSO NOT SEALED AT BOTTOM BOTH ALLOWING WATER TO ENTER IN BEHIND WALL AND DETERIORATING STRUCTURE, SHOWER ROD MADE OF WOOD, WOOD CABINET ROTTED AT BOTTOM, LIGHT SWITCH MISSING COVER PLATE, A/C UNITS IN BEDROOM WINDOWS AND ALSO WINDOWS HAS ROD IRON BARS ON ALL WINDOWS WHICH DO NOT HAVE BREAK AWAYS CAUSE EGREES PROBLEMS IN BOTH BEDROOMS, UNIT HAS NO SMOKE DETECTOR INSTALLED, SOME CONVENIENCE OUTLETS IN L/R DOES NOT WORK, FRONT DOOR HAS BROKEN SLATS ALLOWING ALL ELEMENTS TO ENTER LIVING SPACE, WEATHER STRIPPING MISSING AND OR DETERIORATED TO A POINT OF NOT SEALING DOOR, ALSO STRICKER PLATE MISSING FRONT DOOR AS NOT TO SECURE PROPERLY, ELECTRICAL COVER PLATES MISSING FROM L/R, KITCHEN DOOR SCRAPES ON FLOOR AND DOES NOT OPEN ALL THE WAY, VYNIL IN KITCHEN RIPPED, MISSING TRANSITION STRIP BETWEEN L/R AND KITCHEN FLOOR AND TILES ARE PEELING UP, KITCHEN SEWER DRAIN LINE MISSING CAP EXTERIOR, 100 AMP ELECTRICAL SERVICE LOOKS NEWER, 60 AMP BREAKER WITH 1- 15 AMP BREAKER INSTALLED, WEATHER PROOF BOX NO COVER, USING POWER STRIP CORDS ALL THROUGH OUT THE UNIT INTERIOR AND EXTERIOR HAVING ALOT OF PLUGS PLUGED INTO THEM, HAS WASHER OUTSIDE IN BACK YARD DRAIN LINE NOT INSTALL PROPERLY, HAS ERECTED A BLOCK BUILDING IN REAR ON SOUTHEAST CORNER OF LOT, THIS IS BUILT IN FORM OF ANOTHER RENTAL, UNIT IS NOT FINISHED OR OCCUPIED AT THIS TIME, WILL DO RESEARCH AT D.S.D TO SEE IF PERMITTED WHICH I DO NOT THINK SO BECAUSE OF SET BACKS RIGHT ON LOT LINE TO SOUTH AND EAST N.O. TO FOLLOW. |