Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FOLLOW UP CODE ENFORCE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/18/2009 | INSP - FOLLOW UP CODE ENFORCE | Approved | No follow up since 2005. Case closed. | |
| 12/29/2005 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | T05DV01094, PLEASE REFER TO THIS NUMBER. | |
| 12/15/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | 12/12/03, REVISITED SITE, TOOK PICTURES, REWALKED ALL OF PROPERTY AND FOUND THAT NOT MUCH HAS BEEN DONE TO PROPERTY SINCE JULY, SPACE 16- VAC. SPACE EXPOSED WATER LINE/GAS LINE PIECE OF REBAR STICKING UP OUT OF THE GROUND OPEN SEWER LINE MAIN WATER SUPPLY LINE LEAKING MAIN WATER SUPPLY LINE TO MOBIL HOME LEAKING ELECTRICAL LINE HAS BEEN CUT A HANGING ON TELEPHONE POLE BACKER BOARD LOOSE, AND NEEDS PAINTING TO PROTECT AND SEAL, BOTH SIDES ELECTRICAL METER PANEL FUSE RECEPTACLES ARE DRY ROTTED AND LOSING OUTER PROTECTION COVERING, CRUMBLING APART CONVENIENCE OUTLET WITH FUSE RECEPTACLE BURNT AND EXPOSED. SPACE 17 VAC. TRAILER TRAILER OPEN UNSECURED MAIN WATER SUPPLY LEAK AT METER EXPOSED ELECTRICAL AT EXTERIOR WALK WAY LIGHT POST FIXTURE, GAS IS ON TO METER SPACE 18, EXPOSED ELECTRICAL WIRING INSIDE METER BOX BACKER BOARD IN NEED OF PAINT TO PROTECT AND SEAL WOOD SPACE 19 MAIN WATER SUPPLY LEAK AT METER HOSE BIBB LEAKING, ALSO WATER LEAKING UNDER TRAILER BACKER BOARD NEEDS PAINTED TO PROTECT WOOD FRONT SIDE SHOWS 2 NEW METERS, APPEARS SPACE 19 ONLY BEING SUPPLIED BY 30 AMP BREAKER, ON BACK SIDE HAS DOUBLE LUGGING IN SERVICE PANEL, SPACE 21 ELECTRICAL SERVICE PANEL HAS NO BACKER BOARD AND IS LOOSE ON POLE, SERVICE PANEL BOX MISSING KNOCK OUT PLUG, COVER LID BROKEN SPACE 22 HOT WATER TANK LEAKING OPEN FUSE RECEPTACLE, HOT, LEFT SIDE DETERIORATED AND PROTECTIVE COATING CRUMBLING OFF DISCONNECT BROKEN BACKER BOARD IN NEED OF PAINTING TO SEAL AND PROTECT 40 AMP ELECTRICAL SUPPLY CORD LAYING ON GROUND AND IS TRIP HAZARD UPPER ELECTRICAL SERVICE BOX HAS FUSSES MISSING AND IS HOT, HAS SPLICED WIRES GOING TO BOTH METERS SPACE 24 BACKER BOARD IN NEED OF PAINT TO SEAL AND PROTECT WOOD SPACE 25 HAS NEW ELECTRICAL SERVICES INCONDESENT LIGHT AND FIXTURE HANGING IF FRONT OF TRAILER SOCKET AND WIRING EXPOSED TO ELEMENTS EXPOSED PVC PIPING TO WASHER CONNECTION, SPACE 27 HAS NEW ELECTRICAL METERS INSTALLED AND IS ON BRERAKERS SPACE 41 EMPTY MAIN ELECTRICAL SERVICE TO COMPLETE PARK HAS DETERIORATED WOOD IN BEHIND AND IN NEED OF PAINT TO SEAL AND PROTECT EXPOSED WOOD SPACE 102 DISCONNECT NOT OPERATING PROPERLY CAN NOT FIND MARKING FOR RATING ON ELECTRICAL SUPPLY CORD, BEING USED AS EXTENSION CORD BACKER BOARD IN NEED OF PAINT TO PROTECT AND SEAL WOOD SEWER CONNECTION NOT PROPERLY INSTALLED RAMADA HEIGHT IS ONLY 6' SPACE 14 ELECTRICAL SERVICE DISCONNECT BROKEN 50 AMP CORD ON 60 AMP SERVICE ELECTRICAL WIRING INSIDE OF SERVICE PANEL BOX DETERIORATING AND CRACKING BACKER BOARD IN NEED OF PAINT TO SEAL AND PROTECT WOOD BOTTOM SERVICE BOX NEEDS TO BE SECURED TO BACKER BOARD HAS OPEN SEWER MISSING SEWER CAP CAN SEE WHERE HAS OVER FLOWED ON TO GROUND WEST END OF TRAILER PARK, CENTER, WEST OF TRAILER 8, SPACE VAC. OPEN SEWER LINE, SEWAGE ON GROUND TELEPHONE POLE LISTING TO A POINT NEEDING TO 2X6 BRACES TO HELP HOLD IN PLACE SPACE 8 OPEN SEWER LINE, SEWAGE ON GROUND OPEN AND EXPOSED ELECTRIC TRAILER PULLED INTO SPACE TO FAR BACK CAN NOT OPEN ELECTRICAL SERVICE PANEL LID ALL THE WAY TO ACCESS TO WORK ON EXPOSED WIRING TOP BOTTOM BOX WIRED DIRECTLY BY PASSING FUSE PROTECTION AND DISCONNECT 4X4 POST IN GROUND WITH CONVENIENCE OUTLET, HAS WIRES COMMING FROM TOP OF BOX, HAS BEEN CUT OFF NEWER HOT WATER TANK INSTALLED, FLUE PIPE TO SHORT, NO PRV DRAIN PIPE INSTALLED TO GROUND, NO SHUT OFF ON WATER SUPPLY LINE TO TANK SPACE 13 OPEN SEWER LINE, CLAY PIPE BROKEN, HOLE DUG EXPOSING SUCH LINE HOT WATER TANK, NO PRV DRAIN LINE INSTALLED TO GROUND NO WATER SUPPLY SHUT OFF TO TANK SPACE 4 ELECTRIC BOX OPEN AND HOT BROKEN DISCONNECT IN ELECTRICAL SERVICE PANEL HAS INSTALLED ROMEX COMMING FROM ELECTRICAL PANEL BOX GOING OVER MOBIL HOME, OPEN AND EXPOSED TO TELEPHONE POLE CONNECTED TO A LIGHT WITH EXPOSED WIRING UNDER LIGHT SEWAGE ON GROUND, CAP HELD ON BY 2 BLOCKS ON TOP OF CAP 4X4 POST LISTING AND LEANING SPACE 3 ELECTRIC SERVICE PANEL LOOSE AT BACKER BOARD TELEPHONE POLE LISTING AND LEANING TO NORTH SEVERLY LAUNDRY ROOM HAS APT. ON TOP OF LAUNDRY ROOM, THERE IS NO TRUE 1 HOUR FIRE RATING TO SEPERATE AND PROTECT UNIT FROM FIRE APT BALCONY OR PATIO SUPPORTS HAS 12 SPAN TO SUPPORT BALCONY OR PATION AREA EXTERIOR OF BLOCK BUILDING HAS SEVERAL CONVENIENCE OUTLETS AND OR LIGHT SWITCHES THAT ARE NOT WEATHER PROTECTED EAST SIDE OF BUILDING HAS NEW ELECTRICAL SERVICE INSTALLED FOR APT UPSTAIRS #7 SEVERAL FEET OF NEW FLUE PIPING INSTALLED ON SOUTH SIDE OF BUILDING AND ON WEST SIDE OF BUILDING HOSE BIBB LEAKING BUILDING HAS SEVERAL AREAS WHERE HOLES WHERE KNOCKED THROUGH AND NOT RESEALED. INSIDE LAUNDRY ROOM OPEN AND EXPOSED SEWER LINES EXPOSED ELECTRICAL DRYWALL WALL MISSING FROM WALLS AND CEILING HAS NO 1 HOUR FIRE SEPERATION FROM LAUNDRY CIELING TO APT FLOOR FLOURESENT LIGHT TUBES NOT PROTECTED ELECTRICAL ADDED FOR WASHERS AND FOR DRYERS PLUMBING ADDED FOR WASHERS WASHER DRAIN LINES TO SEWER CONNECTIONS |
|
| 07/14/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | 7/10/03, HAND DELIVERED VACANT AND UNSECURED STRUCTURE N.O. TO VICTORIA YOUNG PROPERTY MANAGER, FOR 5 DAYS TO SECURE ALL OPEN AND UNSECURED STRUCTURES AND BUILDINGS ON PROPERTY, THERE IS EVIDENCE OF HOUSING VAGRANTS IN OPEN AND UNSECURED STRUCTURES, AT THIS TIME VICTORIA STATED THAT MOBIL HOME SHOULD BE GONE BY THE WEEK END. ALSO RECEIVED 2 FAXES WITH LETTER HEAD FROM VICTORIA WHICH CAME FROM STAN ASH GOING TO OFFICER MILLER OF T.P.D. STATING AUTHORIZATION TO ARREST ANY AND ALL TRESPASSERS IN ANY OF THE UNITS IN WHICH THEY DO NOT BELONG, FAXES IN FILE. F/U 7/18/03 |