Case: T03DV00586

Parcel: 107142270


Addresses:

2433 N CASTRO AV

Inspection Status: Approved

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Date Description Inspector Results Comments
05/18/2009 INSP - FOLLOW UP CODE ENFORCE Approved No follow up since 2005. Case closed.
12/29/2005 INSP - FOLLOW UP CODE ENFORCE Correction Required T05DV01094, PLEASE REFER TO THIS NUMBER.
12/15/2003 INSP - FOLLOW UP CODE ENFORCE Correction Required 12/12/03, REVISITED SITE, TOOK PICTURES, REWALKED ALL OF PROPERTY AND FOUND THAT NOT MUCH HAS BEEN DONE TO PROPERTY SINCE JULY,
SPACE 16- VAC. SPACE
EXPOSED WATER LINE/GAS LINE
PIECE OF REBAR STICKING UP OUT OF THE GROUND
OPEN SEWER LINE
MAIN WATER SUPPLY LINE LEAKING
MAIN WATER SUPPLY LINE TO MOBIL HOME LEAKING
ELECTRICAL LINE HAS BEEN CUT A HANGING ON TELEPHONE POLE
BACKER BOARD LOOSE, AND NEEDS PAINTING TO PROTECT AND SEAL, BOTH SIDES
ELECTRICAL METER PANEL FUSE RECEPTACLES ARE DRY ROTTED AND LOSING OUTER PROTECTION COVERING, CRUMBLING APART
CONVENIENCE OUTLET WITH FUSE RECEPTACLE BURNT AND EXPOSED.
SPACE 17 VAC. TRAILER
TRAILER OPEN UNSECURED
MAIN WATER SUPPLY LEAK AT METER
EXPOSED ELECTRICAL AT EXTERIOR WALK WAY LIGHT POST FIXTURE, GAS IS ON TO METER
SPACE 18,
EXPOSED ELECTRICAL WIRING INSIDE METER BOX
BACKER BOARD IN NEED OF PAINT TO PROTECT AND SEAL WOOD
SPACE 19
MAIN WATER SUPPLY LEAK AT METER
HOSE BIBB LEAKING, ALSO WATER LEAKING UNDER TRAILER
BACKER BOARD NEEDS PAINTED TO PROTECT WOOD
FRONT SIDE SHOWS 2 NEW METERS, APPEARS SPACE 19 ONLY BEING SUPPLIED BY 30 AMP BREAKER, ON BACK SIDE HAS DOUBLE LUGGING IN SERVICE PANEL,
SPACE 21
ELECTRICAL SERVICE PANEL HAS NO BACKER BOARD AND IS LOOSE ON POLE, SERVICE PANEL BOX MISSING KNOCK OUT PLUG, COVER LID BROKEN
SPACE 22
HOT WATER TANK LEAKING
OPEN FUSE RECEPTACLE, HOT, LEFT SIDE DETERIORATED AND PROTECTIVE COATING CRUMBLING OFF
DISCONNECT BROKEN
BACKER BOARD IN NEED OF PAINTING TO SEAL AND PROTECT
40 AMP ELECTRICAL SUPPLY CORD LAYING ON GROUND AND IS TRIP HAZARD
UPPER ELECTRICAL SERVICE BOX HAS FUSSES MISSING AND IS HOT,
HAS SPLICED WIRES GOING TO BOTH METERS
SPACE 24
BACKER BOARD IN NEED OF PAINT TO SEAL AND PROTECT WOOD
SPACE 25
HAS NEW ELECTRICAL SERVICES
INCONDESENT LIGHT AND FIXTURE HANGING IF FRONT OF TRAILER SOCKET AND WIRING EXPOSED TO ELEMENTS
EXPOSED PVC PIPING TO WASHER CONNECTION,
SPACE 27
HAS NEW ELECTRICAL METERS INSTALLED AND IS ON BRERAKERS
SPACE 41 EMPTY
MAIN ELECTRICAL SERVICE TO COMPLETE PARK
HAS DETERIORATED WOOD IN BEHIND AND IN NEED OF PAINT TO SEAL AND PROTECT EXPOSED WOOD
SPACE 102
DISCONNECT NOT OPERATING PROPERLY
CAN NOT FIND MARKING FOR RATING ON ELECTRICAL SUPPLY CORD, BEING USED AS EXTENSION CORD
BACKER BOARD IN NEED OF PAINT TO PROTECT AND SEAL WOOD
SEWER CONNECTION NOT PROPERLY INSTALLED
RAMADA HEIGHT IS ONLY 6'
SPACE 14
ELECTRICAL SERVICE DISCONNECT BROKEN
50 AMP CORD ON 60 AMP SERVICE
ELECTRICAL WIRING INSIDE OF SERVICE PANEL BOX DETERIORATING AND CRACKING
BACKER BOARD IN NEED OF PAINT TO SEAL AND PROTECT WOOD
BOTTOM SERVICE BOX NEEDS TO BE SECURED TO BACKER BOARD
HAS OPEN SEWER MISSING SEWER CAP
CAN SEE WHERE HAS OVER FLOWED ON TO GROUND
WEST END OF TRAILER PARK, CENTER, WEST OF TRAILER 8, SPACE VAC.
OPEN SEWER LINE, SEWAGE ON GROUND
TELEPHONE POLE LISTING TO A POINT NEEDING TO 2X6 BRACES TO HELP HOLD IN PLACE
SPACE 8
OPEN SEWER LINE, SEWAGE ON GROUND
OPEN AND EXPOSED ELECTRIC
TRAILER PULLED INTO SPACE TO FAR BACK CAN NOT OPEN ELECTRICAL SERVICE PANEL LID ALL THE WAY TO ACCESS TO WORK ON
EXPOSED WIRING TOP
BOTTOM BOX WIRED DIRECTLY BY PASSING FUSE PROTECTION AND DISCONNECT
4X4 POST IN GROUND WITH CONVENIENCE OUTLET, HAS WIRES COMMING FROM TOP OF BOX, HAS BEEN CUT OFF
NEWER HOT WATER TANK INSTALLED, FLUE PIPE TO SHORT, NO PRV DRAIN PIPE INSTALLED TO GROUND, NO SHUT OFF ON WATER SUPPLY LINE TO TANK
SPACE 13
OPEN SEWER LINE, CLAY PIPE BROKEN, HOLE DUG EXPOSING SUCH LINE
HOT WATER TANK, NO PRV DRAIN LINE INSTALLED TO GROUND
NO WATER SUPPLY SHUT OFF TO TANK
SPACE 4
ELECTRIC BOX OPEN AND HOT
BROKEN DISCONNECT IN ELECTRICAL SERVICE PANEL
HAS INSTALLED ROMEX COMMING FROM ELECTRICAL PANEL BOX GOING OVER MOBIL HOME, OPEN AND EXPOSED TO TELEPHONE POLE CONNECTED TO A LIGHT WITH EXPOSED WIRING UNDER LIGHT
SEWAGE ON GROUND, CAP HELD ON BY 2 BLOCKS ON TOP OF CAP
4X4 POST LISTING AND LEANING
SPACE 3
ELECTRIC SERVICE PANEL LOOSE AT BACKER BOARD
TELEPHONE POLE LISTING AND LEANING TO NORTH SEVERLY
LAUNDRY ROOM
HAS APT. ON TOP OF LAUNDRY ROOM, THERE IS NO TRUE 1 HOUR FIRE RATING TO SEPERATE AND PROTECT UNIT FROM FIRE
APT BALCONY OR PATIO SUPPORTS HAS 12 SPAN TO SUPPORT BALCONY OR PATION AREA
EXTERIOR OF BLOCK BUILDING HAS SEVERAL CONVENIENCE OUTLETS AND OR LIGHT SWITCHES THAT ARE NOT WEATHER PROTECTED
EAST SIDE OF BUILDING HAS NEW ELECTRICAL SERVICE INSTALLED FOR APT UPSTAIRS #7
SEVERAL FEET OF NEW FLUE PIPING INSTALLED ON SOUTH SIDE OF BUILDING AND ON WEST SIDE OF BUILDING
HOSE BIBB LEAKING
BUILDING HAS SEVERAL AREAS WHERE HOLES WHERE KNOCKED THROUGH AND NOT RESEALED.
INSIDE LAUNDRY ROOM
OPEN AND EXPOSED SEWER LINES
EXPOSED ELECTRICAL
DRYWALL WALL MISSING FROM WALLS AND CEILING
HAS NO 1 HOUR FIRE SEPERATION FROM LAUNDRY CIELING TO APT FLOOR
FLOURESENT LIGHT TUBES NOT PROTECTED
ELECTRICAL ADDED FOR WASHERS AND FOR DRYERS
PLUMBING ADDED FOR WASHERS
WASHER DRAIN LINES TO SEWER CONNECTIONS
07/14/2003 INSP - FOLLOW UP CODE ENFORCE Correction Required 7/10/03, HAND DELIVERED VACANT AND UNSECURED STRUCTURE N.O. TO VICTORIA YOUNG PROPERTY MANAGER, FOR 5 DAYS TO SECURE ALL OPEN AND UNSECURED STRUCTURES AND BUILDINGS ON PROPERTY, THERE IS EVIDENCE OF HOUSING VAGRANTS IN OPEN AND UNSECURED STRUCTURES, AT THIS TIME VICTORIA STATED THAT MOBIL HOME SHOULD BE GONE BY THE WEEK END. ALSO RECEIVED 2 FAXES WITH LETTER HEAD FROM VICTORIA WHICH CAME FROM STAN ASH GOING TO OFFICER MILLER OF T.P.D. STATING AUTHORIZATION TO ARREST ANY AND ALL TRESPASSERS IN ANY OF THE UNITS IN WHICH THEY DO NOT BELONG, FAXES IN FILE. F/U 7/18/03