Inspection History Details
Inspection Status: Correction Required
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/27/2003 | INSP - INITIAL CODE ENFORCMENT | Correction Required | RECEIED CALL FROM OWNER STATING ALL REPAIRS COMPLETE. WORKING WITH DSD TO PASS CODE COMPLAINT PERMIT. | |
| 08/12/2003 | INSP - INITIAL CODE ENFORCMENT | Correction Required | RECEIVED CALL FROM OWNER STATING ALL REPAIRS ARE COMPLETED. ALL ELECTRIC HAS BEEN APPROVED UNDER PERMIT. | |
| 08/01/2003 | INSP - INITIAL CODE ENFORCMENT | Correction Required | RECEIVED NUMEROUS CALLS FROM OWNER. STATING ALL ELECTRICAL REPAIRS HAVE BEEN COMPLETED UNDER PERMIT. OWNER HAS HIRED CONTRACTOR TO REPLACE EXISITING EXTERIOR DOORS IN ROOM ADDITION WITH NEW. NEW SMOKE DETECTORS INSTALLED (3). ALLREPAIRS COMPLETED UNDER PERMIT. OWNER WILL CALL FOR INSPECTION NEXT WEEK. STORAGE ROOM ELECTRICAL REMOVE. STORAGE ROOM MUST STILL BE MOVED FROM LOT LINE AND ATLEAST 10' AWAY FROM ROOM ADDITION. F/U 8/7/03. | |
| 07/17/2003 | INSP - INITIAL CODE ENFORCMENT | Correction Required | OWNER CONTACTED INSPECTOR WITH STATUS THAT PERMIT # T03CM03507 HAS BEEN ISSUED TODAY FOR CODE COMPLIANCE. RECEIVED FAX FROM OWNER STATING ALL REPAIRS WILL BE COMPLETED BY 8/2/03. | |
| 06/23/2003 | INSP - INITIAL CODE ENFORCMENT | Correction Required | OWNER HAS KEPT IN CONTACT WITH INSPECTOR ON STAUS OF PERMITS. OWNER HAS HIRED ARCHITECT FOR DRAWINGS FOR CODE COMPLIANCE PERMIT FOR ROOM ADDITION AND ELECTRICAL WORK ADDED.SEND NOTICE. | |
| 06/18/2003 | INSP - INITIAL CODE ENFORCMENT | Correction Required | PLUMBING ISSUES HAVE BEEN ABATED BY OWNER WHO HAD MAINT. PERSON REMOVE DEBRIS FROM DRAINS. DRAINS ARE WORKING PROPERLY AT THIS TIME. SEND NOTICE. | |
| 06/17/2003 | INSP - INITIAL CODE ENFORCMENT | Correction Required | FOUND NUMEROUS MIN-HSG VIOLATIONS: EXPOSED WIRING ROMEX TO STORAGE ROOM FROM ROOM ADDITION. EXPOSED WIRING IN CARPORT TO SUBPANEL. HAZARDOUS ELECTRICAL AT MAIN SERVICE PANEL. EXPOSED WIRING TO SECURITY LIGHT IN CARPORT. CARPORT EWNCLOSED TO LIVEABLE BEDROOM. CONVENIENCE OUTLET NOT SECURED TO WALL IN ADDITION. A/C UNIT ON SAME CIRCUIT. BOTH EXTERIOR DOORS TO ADDITION LACK REQUIRED W/S AND SWEEEPS. MAIN HOUSE FOUND FRONT ENTRY DOORDOES NOT OPERATE PROPERLY. COMING OFF HINGES. BATHROOM TUB DOES NOT DRAIN PROPERLY. MASTER BATH SHOWER DOES NOT DRAIN PROPERLY. MASTER BATH VANITY LEAKS AT TRAP. NO SMOKE DETECTOR IN HALLWAY. REAR BEDROOM EXTERIOR DOOR LACKS W/S. SUBPANEL REAR BEDROOM LACKS REQUIRED COVER PANEL. CHECK RECORDS FOR ROOM ADDITION PERMIT AND ELECTRICAL CIRCUITS ADDED TO MAIN SERVICE. CONTACTED OWNER WITH 24 HOUR NOTICE TO REPAIR BATHROOM DRAINS. SEND NOTICE. |