Inspection History Details
Inspection Status: Closed
Inspection History: INSP - FOLLOW UP CODE ENFORCE
Case Number - T03DV00506
Inspection Description - INSP - FOLLOW UP CODE ENFORCE
Inspection Status - Closed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/05/2004 | INSP - FOLLOW UP CODE ENFORCE | Closed | UNIT 220 WAS INSPECTED AT THE REQUEST OF MANAGEMENT. NO VIOLATIONS. UNIT CAN BE RENTED.THERE ARE NO VIOLATIONS AT THIS TIME. ALL VIOLATIONS OF THE SABER WERE ABATED. CLOSE CASE. | |
12/15/2003 | INSP - FOLLOW UP CODE ENFORCE | Not ready for Inspection | UNITS 206, 216, AND 128 WERE INSPECTED TODAY FOR COMPLIANCE. UNIT 206 WAS FINE. UNIT 216 NEEDEDWEATHER STRIPPING ON THE FRONT DOOR. UNIT 128 WAS LACKING ONE STOVE BURNER WHICH WAS ON ORDER. ALL UNITS WERE TOTALLY REFURBISHED - NEW PAINT, NEW APPLIANCES, NEWSMOKE DETECTORS, CARPETS CLEANED, ETC. THEY WERE GRANTED PERMISSION TO RENT THE UNITS. | |
11/24/2003 | INSP - FOLLOW UP CODE ENFORCE | No Violation | I WAS SUBPOENAED BY THE COMPLEX TO APPEAR IN COURT. TENANT WAS BEING EVICTED FOR NON PAYMENT OF RENT. THE TENANTS ATTORNEY IS THE PERSON THAT ENDED UP CALLING ME AS A WITNESS TO TESTIFY THAT THE UNIT WAS UNDER NOTICE AND WAS TO BE INSPECTED BEFORE IT WAS RENTED OUT. THE OTHER SIDE THEN QUESTIONED ME ON WHETHER OR NOT THE UNIT WAS UNFIT TO OCCUPY WHICH IT WAS NOT. IT WAS MORE ASTECTICS, NOTHING MADE THE UNIT UNFIT OR UNHABITABLE, AND THAT IS WHAT I TESTIFIED TO. | |
10/28/2003 | INSP - FOLLOW UP CODE ENFORCE | Violation | CITATION ISSUED TO JOHN P & KATHY A MCKINLEY & DAVID L & SUSAN R CROCKETT | |
10/28/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | INSPECTED UNIT TODAY. MANAGEMENT HAD CALLED ON 10/24/03 STATING EVERYTHING WAS DONE BUT I WAS BUSY AT 2 OTHER SABER PROJECTS AND TOLD THEM I COULD MAKE IT UNTIL MONDAY OR TUESDAY. THE TENANT STATED TODAY THAT NO VIOLATIONS EXISTED. I INSPECTED THE UNIT ANYWAY AND FOUND A CENTER HOLDER PIECE OFF THE WINDOW. MANAGEMENT STATED IT WAS ON ORDER. I REQUESTED THAT A PIECE OF FOAM BE INSTALLED UNTIL THE PIECE CAME IN FOR THE WINDOW. WILL CHECK BACK ON FRIDAY, IF NOT DONE, ANOTHER CITATION COULD BE WRITTEN.FOUND NO VIOLATIONS AT TIME OF REINSPECTION. |
|
10/21/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | INSPECTED UNIT 128 TODAY. UNIT HAD BEEN COMPLETELY REFURBISHED, HOWEVER, I FOUND A COVER PLATE MISSING, A BROKEN WINDOW IN THE BEDROOM THAT THE TENANT STATED JUST HAPPENED, A KICK PLATE MISSING UNDER THE DISHWASHER, A WATER LEAK ABOVE THE SHOWER ON THE WALL THAT THE TENANT STATED JUST HAPPENED AND 2 STOVE BURNERS NOT WORKING THAT WERE UNPLUGGED. UNIT WAS TO BE REINSPECTED BEFORE IT WAS OCCUPIED PER PREVIOUS NOTICE. UNIT WAS OCCUPIED. SPOKE WITH MANAGEMENT AND SHE PRESENTED ME WITH 2 LETTERS THAT THEY WERE TRYING TO GET IN TO DO THE WORK THE LAST COUPLE OF DAYS AND THE TENANT REFUSED THEM ENTRY. THEY ALSO PRESENTED ME WITH A POSTING OF A 48 HOUR NOTICE TO THE TENANT THAT THEY WOULD BE IN BETWEEN 10 A.M. AND 2 P.M ON THE 23RD TO MAKE THE REPAIRS ANYWAY. | |
08/29/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | REINSPECTED THE REMAINING VIOLATIONS TODAY. ALL THE ADDRESSING AND A NEW SIGN FOR THE COMPLEX WAS INSTALLED. THE FENCE IN QUESTION WAS REMOVED. THE VIOLATIONS IN THE OFFICE WEE ABATED. NEW LIGHTING WAS INSTALLED IN THE LAUNDRY ROOM. THE POOL AREA VIOLATIONS HAVE BEEN ABATED. ALL VIOLATIONS AT THE COMPLEX HAVE BEEN ABATED AT THIS TIME EXCEPT FOR THE WATER HEATER PERMIT NEEDS TO BE FINALED AND A FEW VACANT UNITS REINSPECTED BEFORE THE CASE CAN BE CLOSED. FOLLOW UP ON SEPTEMBER 5, 2003. | |
08/28/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | THE REMAINING OF THE 57 UNITS WERE INSPECTED ON WEDNESDAY AFTERNOON AND EVENING. THEY ARE ALL IN COMPLIANCE. THE FALLING FENCE IN THE BACK STILL NEEDS REPAIRS OR REMOVED. THE OFFICE STILL HAS EXPOSED WIRES. THE WATER HEATER PERMIT HAS NOT BEEN FINALED. WILL FOLLOW UP ON FRIDAY THE 29TH. THE DEADLINE PER THE NOTICE AND ORDER IS THE 29TH. | |
08/26/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | APPROXIMATELY 13 UNITS WERE INSPECTED ON MONDAY NIGHT, 8/25/03. THE REMAINING UNITS SHALL BE INSPECTED ON WEDNESDAY MORNING AND WEDNESDAY EVENING PER THE NOV. THE DEADLINE IS 8/29/03. | |
08/21/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | PER SABER NOTICE AND ORDER AND CECI'S APPROVAL. INSPECTIONS WERE SCHEDULED FOR AFTER 5:00P.M. IN THE EVENING STARTING WEDNESDAY THE 20TH OF AUGUST, 2003. UNITS 101,103, 203, 204, 105, 108, 109, 111, 209, 113, 213, 118, 121, 221, ARE ALL IN COMPLIANCE. VACANT UNITS 117, 129, 202, 208, ARE IN COMPLAINCE AND CAN BE RENTED. UNDER THE AUTHORITY TO INSPECT, UNITS 104, 106, 107, 115, 116, 201 WERE ALL INSPECTED. 104 HAD WATER DAMAGE AND LEAK UNDER AC UNIT. 106 HAD NO SMOKE ALARM AND THE TOILET HANDLE WAS NOT WORKING PROPERLY. 107, 115,116, AND 201 ARE IN COMPLIANCE. tHESE UNITS WERE ALL INSPECTED WEDNESDAY EVENING THE 20TH OF AUGUST, 2003. |
|
07/31/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | INSPECTED UNIT 117 TODAY FOR COMPLIANCE AT THE MANAGERS REQUEST. IT WAS PREVIOUSLY VACANT. THE NOTICE AND ORDER REQUIRES THEM TO CONTACT DNR AND HAVE ALL VACANT UNITS INSPECTED BEFORE THEY ARE OCCUPIED. THE UNIT HAS NO VIOLATIONS. A NEW AIR CONDITIONER WAS ALSO INSTALLED WHICH INCLUDED A REMOTE CONTROL. | |
07/29/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | THE NOTICE WAS COMPLETED ON 7/28/03 AND GIVEN TO CECI FOR REVEIW. ONCE IT GETS PROOF READ BY CECI, IT WILL BE POSTED ON THE PROPERTY AND SENT OUT CERTIFIED AND REGULAR MAIL. ONCE THE OWNER RECEIVES IT, THEY WILL HAVE 30 DAYS TO MAKE THE CORRECTIONS. SOME OF THE CORRECTIONS HAVE ALREADY BEEN MADE. | |
07/29/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | I POSTED THE NOTICE AND ORDER TODAY AT THE OFFICE OF THE PROPERTY. IT WILL ALSO GO OUT CERTIFIED MAIL AND REGULAR MAIL. THERE WAS ALSO A VERY LARGE DUMPSTER ON THE PROPERTY AND THE PLACE WAS BEING CLEANED UP. | |
07/02/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 111 SMOKE DET MISSING. NO WEATHER SEALS ON FRONT DOOR. FRONT DOOR LOCKS BROKEN AND LOOSE. |
|
07/02/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT108 BROKEN OUTLET IN KITCHEN. EX-FAN MISSING GREASE FILTER. A/C UNIT NEEDS MAINT, DIRTY. NO WEATHER SEALS ON FRONT DOOR. |
|
07/02/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 101 KITCHEN CABNETS LLOSE ON WALL. SMOKE DET NOT WORKING. LOOSE OUTLET IN BEDROOM WALL. |
|
07/02/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 110 KITCHEN CABNETS LOOSE ON WALL, SMOKE DET NOT WORKING, MISSING OUTLET COVER FOR /C UNIT. NO WEATHER SEALS ON FRONT DOOR. |
|
07/02/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 113 SMOKE DET. MISSING BATTERY. BATHROOM LIGHT FIXTURE COVER MISSING. NO WEATHER SEALS ON FRONT DOOR. |
|
07/02/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 213 DOOR STOOP IN LOOSE. MISSING OUTLET COVERS IN KITCHEN. GFI OUTLET IN BATHROOM BROKEN. OUTLET IN BEDROOM HANGING FROM WALL. |
|
07/02/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 118 KITCHEN DRAIN LEAKING. NO WORKING SMOKE DET. BROKEN LOCK AT FRONT DOOR. |
|
07/02/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 218 SMOKE DET NOT WORKING. GFI OUTLET IN BATH NOT WORKING. IMPROPER DOOR LOCK . |
|
07/02/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 217 SMOKE DET. NOT WORKING. NO WEATHER SEALS ON FRONT DOOR. |
|
07/02/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 120 FRONT DOOR TRIM BROKEN APART. A/C SYSTEM NOT COOLING PROPER , OLD SYSTEM. |
|
07/02/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 119 BROKEN COVER PLATE IN THE KITCHEN. NO WEATHER SEALS ON FRONT DOOR. |
|
07/02/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 221 BATHROOM EX-FAN LOOSE. DOUBLE KEYED LOCK ON FRONT DOOR. NO KITCHEN EX-FAN AT THE STOVE. |
|
07/02/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 224 BATHROOM DRAIN LEAKING. TOLIET TANK CONTROLS BROKEN. ROACHES. PLASTER HOLES AND WATER DAMAGE UNDER KITCHEN SINK. |
|
07/02/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 222 SMOKE DET. NOT WORKING. EX-FAN MISSING GREASE FILTER. |
|
07/02/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | ALL UNITS WERE INSPECTED EXCEPT 127, 128, 104, 106, 107, 114, 115, 116, AND 205. THE MANAGER IS TRYING TO GET THEM SCHEDULED FOR US. | |
06/30/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | JESS, GLENN, AND I INSPECTED APPROXIMATELY 10 UNITS TODAY. MINOR HOUSING VIOLATIONS WERE FOUND IN EACH UNIT. THE MANAGER AND MAINTENANCE MAN WERE ALSO PRESENT. UNIT #214 HAD THE OPEN GROUND REPAIRED IN HIS UNIT. INSPECTIONS WILL CONTINUE ON 7/1/03. | |
06/30/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 126 NO WORKING SMOKE DECT. HOLE IN CLOSET TO OUTSIDE UNIT. DOUBLE KEYED LOCKS ON REAR DOOR. NO WEATHER SEALS ON BOTH DOORS. BARS ON CHILDS BEDROOM WINDOW. GFI OUTLET IN BATHROOM NOT WORKING. |
|
06/30/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 125; MISSING KITCHEN FIXTURE COVER. BEDROOM DOOR BROKEN APART. NO SMOKE DECT. MISSING ALL OUTLET COVER PLATES IN BATHROOM PEELING PAINT IN THE LIVINGROOM FROM OLD WATER LEAK. |
|
06/30/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 124 NO SMOKE DECT. NO WEATHER SEALS ON THE FRONT DOOR. |
|
06/30/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 121. BEDROOM WINDOW BROKEN, COVERED WITH TAPE. WATER LEAKING IN LIVINGROOM. NO SMOKE DECT. |
|
06/30/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 219 BEDROOM WINDOW BROKEN. SMOKE DECT.NOT WORKING. GFI OUTLET NOT WORKING IN THE BATHROOM. NEW HOTWATER HEATER INSTALLED W/O PERMITS. |
|
06/30/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 112 PEELING PAINT IN LIVINGROOM, OLD WATER LEAKS. |
|
06/30/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 209 WEATHER SEALS MISSING ON FRONT DOOR. SMOKE DECT. NOT WORKING FRONT DOOR BROKEN APART. |
|
06/30/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | SABER INSPECTION TODAY APPRX 19 UNITS, INCLUDING THE POOL AREA, STORAGE YARD AND WASROOM, ALSO THE OFFICE. | |
06/30/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 109 MISSING SMOKE DECT. MISSING TWO LIGHT FIXTURE COVERS. |
|
06/30/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | ALL WOOD DECKING IN NEED OF TOTAL REPLACEMENT DUE TOO THE ROTTON FLOOR BASE. | |
06/30/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 203 DOUBLE KEYED LOCK ON THE FRONT DOOR. FRONT DOOR JAMS ROTTON AND BROKEN. DECK PROBLEMS-ROTTON. |
|
06/30/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 204 GFI OUTLET BROKEN IN BATHROOM, POOR WEATHER SEALS ON FRONT DOOR,SINK LEAKING BATHROOM. |
|
06/30/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 103 MICE FOUND INSIDE UNIT WITH A LIZARD . |
|
06/30/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 105 MISSING OUTLET COVER IN BEDROOM, NO SMOKE DECT FOUND IN UNIT. |
|
06/30/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 102 A/C MISSING COVER FOR THE FRONT. GFI OUTLET NOT WORKING IN THE BATHROOM. NO WEATHER SEALS AT THE FRONT DOOR. |
|
06/30/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | ||
06/30/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | GLEN FROM TUCSON FIRE DEPT. ALSO HAS WRITTEN A REPORT AND IS INCLUDED IN THE SABER FILE. | |
06/25/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNITS WERE POSTED BY DNR AND FIRE ON 6/20/03 WITH A LETTER OF INTENT TO INSPECT. I REPOSTED THEM ON 6/23/03. ( ALL 56 UNITS) BECAUSE OF THE POOR RESPONSE. THE TENANTS THAT ARE CALLING IN ARE BEING SCHEDULED FOR INSPECTIONS ON 6/30/03 AND 7/01/03 BETRWEEN 8 AND 5 P.M. UNIT #214 WILL BE INSPECTED TODAY AS SCHEDULED AND AS PROMISED SO THAT THE TENANT DOES NOT HAVE TO MISS WORK. | |
06/25/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | CECI MET ME ON SITE TODAY AND WE WENT THROUGH UNIT #214. THE VIOLATIONS WERE THAT THE SMOKE ALARM IN THE BEDROOM WAS NOT WORKING PROPERLY, AN OPEN GROUND FOUND, HOLE IN CLOSET WALL WHERE A PLUMBING LEAK WAS FIXED AND NOT REPAIRED PROPERLY AND NO ADDRESSING. | |
06/12/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 127; SITE VISIT I MET TENANT, I FOUND THE FOLLOWING ITEMS THAT WILL NEED ABATED PER CITY CODES.; BATHROOM PLASTER LOOSE ABOVE TUB DUE TO A OLD WATER LEAK FROM THE ABOVE BATHROOM. NO DOOR KNOBS ON BEDROOM DOORS. A/C/ NEEDS PROPER MAINT. NO WEATHER SEALS ON BOTH DOORS. REAR DOOR WINDOW FRAME BROKEN AND UNSTABLE. NO WOKING SMOKE DECT. KITCHEN STOVE BASE BROKEN OFF. |
|
06/12/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT;123; FRONT DOOR LOCKS BROKEN. NO WEATHER SEALS ON BOTH DOORS. NO WORKING SMOKE DECT. REAR DOOR WINDOW LOOSE IN FRAME. E-FAN IN BATH BURNED OUT DUE TO OLD WATER DAMAGE. KITCHEN SINK LEAKING AT THE DRAIN. REAR PORCH LIGHT HAS BARE WIRES. CLOSET LIGHT HANGING FROM ELECT. WIRES. SPRAY AT KITCHEN SICK INSTALLED IMPROPER. DISHWASHER FALLING LOOSE FROM BASE, PLASTER LOOSE AND FALLING IN BATH ABOVE THE TUB. |
|
06/12/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT ;;223 KITCHEN SINK DRAIN LEAKING. NO WORKING SMOKE DECT. NO WEATHER SEALS ON BOTH DOORS. REAR DOOR WINDOW FRAME BROKEN.AND UNSTABLE. BEDROOM WINDOW WILL NOT SHUT. BATHROOM OUTLET NOT WORKING. THREASHOLD AT FRONT DOOR BROKEN AND TRIP HAZ. BEDROOM DOOR KNOB BROKEN. E-FAN IN BATHROOM VERY UNSTABLE AND LOOSE INSIDE. THERMOSTAT BROKEN. |
|
06/12/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT 213; UNIT FOUND VACANT AND ABAN. THE POWER IS OFF AT THIS TIME, THE FRONT DOOR IS WIDE OPEN WITH TRASH AND DEBRIES INSIDE, IT SEEMS IF THERE MIGHT BE PEOPLE SLEEPING INSIDE. |
|
06/12/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT ;;203 UNIT IS OPEN AND VACANT AND ABAN. THERE IS TRASH THRU-OUT THE UNIT, NO POWER AT THIS TIME. |
|
06/12/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT ;215; UNIT IS OPEN AT THE FRONT DOOR AND VACA AND ABAN, THERE IS NO POWER AT THIS TIME, THERE IS LOTS OF TRASH ,BEER CANS AND OTHER INSIDE. |
|
06/12/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT;202; UNIT IS ALSO OPEN AT WINDOW AND FRONT DOOR, THERE IS NO POWER INSIDE, THERE IS A FLOOR BOARD UP IN THE KITCHEN THAT WILL NEED TO BE ABATED. |
|
06/12/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | UNIT;207 UNIT ALSO FOUND OPEN AT FRONT DOOR. UNIT IS VERY CLEAN INSIDE AT THIS TIME, NO POWER AT METER. |
|
06/12/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | COMMON AREA: TRASH AND DEBRIES ON SOME DECKS, OLD ICEBOXES, A/C UNITS CHAIRS. |
|
06/12/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | C-6 STATED THAT THIS WILL BE A SABER. |