Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FOLLOW UP CODE ENFORCE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/04/2003 | INSP - FOLLOW UP CODE ENFORCE | Approved | 11/4/03 DID FOLLOW UP INSPECTION. REWIRE OF INTERIOR AND ELECTRICAL HAS BEEN COMPLETED. PERMIT #T03EL01103 WAS FINALED ON 5/16/03. REWIRE PERMIT #T03EL01947 FINALED 10/23/03. NEW FLOORING HAS BEEN INSTALLED, ELECTRICAL HAZARDS HAVE BEEN ABATED. INSTALLATION OF DRAIN PIPE FOR HOT WATER HEATER HAS BEEN COMPLETED. NEW WEATHER STRIPPING INSTALLED ON ENTRY DOORS, BEDROOM DOOR HINGE REPAIRED. ALL VIOLATIONS HAVE BEEN ABATED. OWNER HAS COMPLIED. CLOSE CASE PICTURES WERE TAKEN. NOTE: NEW SMOKE ALARMS WERE CHECKED & WORKING. |
|
| 10/14/2003 | INSP - FOLLOW UP CODE ENFORCE | Violation | RESEARCH DONE IN PERMITS PLUS, ELECTRICAL PERMIT ISSUED FOR UNIT 1 & 2 T03EL01103, APPLIED, APPROVED AND ISSUED 06/06/03 FOR UNIT #1 UNIT #2 T03EL01947 APPLIED, APPROVED AND ISSUED 10/01/03 FOR #2. VISITED SITE ON FOLLOW UP INSP. 70% OF VIOLATIONS HAVE BEEN ABATED, REMAINING ITEMS ARE DRAIN PIPE MISSING AT TPR VALVE, FLUE VENT REMAINS UNABATED, BEDROOM DOOR UNABATED, EXPOSED ELECTRICAL CONDUCTOR NOT IN CONDUIT IN UPPER KITCHEN CABINETS, NEW 100 AMP SERVICE AND REWIRING OF STRUCTURE IS ALMOST COMPLETED. FIXTURES, SWITCHES AND NEW ROMEX HAVE BEEN INSTALLED. ELECTRICAL INTERMEDIATE INSP HAS BEEN APPROVED. DO FOLLOW ON 11/21/03. COURT SCHEDULED FOR 11/24/03/ | |
| 06/19/2003 | INSP - FOLLOW UP CODE ENFORCE | Violation | CITATION ISSUED TO RAMON & MERCEDES L. LEON FOR MIN HOUSING ISSUES | |
| 06/05/2003 | INSP - FOLLOW UP CODE ENFORCE | Violation | INSP. FOLLOW UP DONE ON 6/5/03 NO PROGRESS HAS BEEN MADE. ATTEMPS TO WEATHER PROOF DOORS ARE INADQUATE, COVER PLATE LACKING BEHIND REFIGERATOR. SOUTH WEST BEDROOM DOOR & BATHROOM DOOR HAS NOT BEEN ADDRESSED. BROKEN FLOOR TILES IN KITCHEN. REVERSED HOT NUTERAL IN KITCHEN HAS NOT BEEN ABATED. WILL ISSUE CITATION. | |
| 05/07/2003 | INSP - FOLLOW UP CODE ENFORCE | Violation | VISITED SITE ON FU INSP. OWNER HAS INSTALLED NEW DISCONNECT BOX AND RISER ALONG WITH CIRCUITS FOR WASHING MACHINE AND GFIC OUTLETS LEFT CARD FOR INSP INSIDE. TENANT TO CONTACT ME FOR APP. | |
| 03/28/2003 | INSP - FOLLOW UP CODE ENFORCE | Violation | VISITED SITE-INSP. OF STRUCTURE FOUND THE FOLLOWING ITEMS HAVE NOT BEEN ABATED. REVERSED HOT NUETRAL IN KITCHEN,OPEN GROUND AT WASHING MACHINE & UNGROUNDED RECEPTICAL IN BATH ROOM. UNPROTECTED ROMEX BEHIND WASHING MACHINE AND LACKING WEATHER PROOF OUTLET BOX. BEDROOM DOOR HINGE,HAS NOT BEEN ADDRESSED. FRONT & REAR ENTRY DOORS LACKING WEATHER STRIPPING. HOT WATER HEATER LACKING T.P.R. DRAIN AND BATH ROOM SINK LEAKING FROM PLUMBING UNDERNEIGH & VENT PIPE NOT EXTENDIND ABOVE ROOF AS PER CODE REQUIREMENTS. ITEMS COMPLETED-SMOKE DETECTORS INSTALLED, BEDROOM DOOR CASING REPLACED ALONG WITH NEW KITCHEN WINDOW, HAZARDOUS PLUMBING IN KITCHEN WAS REPAIRED.HAS BEEN ISSUED PERMIT T03EL00428 ON 3/11/03 FOR ELECTRICAL UPGRADE. OWNER HAS MADE ARRANGEMENTS WITH TENANT TO BEGUIN ELECTRICAL REPAIRS ON 4/11/03 THRU 4/18/03. TENANT WILL BE AWAY ON VACTION. DO 30 DAY FOLLOW UP. | |
| 02/07/2003 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | OWNER CAME INTO OFFICE. HECTOR HAS BEEN ILL ALL WEEK. NOT IN OFFICE. OWNER STATES BEDROOM CLOSET DOOR AND JAMB HAS BEEN REPLACED WITH NEW. NO MORE TERMITES. SMOKE DETECTOR INSTALLED. KITCHEN SINK REPAIRED. BOTH EXTERIOR DOORS HAVE W/S AND SWEEP INSTALEED. BROKEN WINDOW GLASS REPLACED IN KITCHEN. OWNER PLANS TO PULL PERMIT FOR 100 AMP SERVICE UPGRADE TO DWELLING. TO ADDRESS ALL ELECTRICAL VIOLATIONS IN QUESTION. EXTENSION GRANTED 30-DAY FOR REMAINING REPAIRS. F/U 30-DAYS. |