Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T03CM05921
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/18/2004 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :*/ 1) SOIL WTR TEST IS OK. 2) BLDG DRAIN IS STUBBED OUT AT TWO WAY C.O. ONLY. 3) 2" WTR SERVICE AT AIR PRESSURE TEST IS OK. 2" WTR IS STUBBED OUT OF BLDG ONLY. | |
06/10/2004 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ NO APPROVED PLANS ON SITE. |
|
06/09/2004 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) MUST PROVIDE 10' WTR TEST ON SYSTEMS. 2) MUST SHADE ENTIRE TRENCH TO TOP OF PIPE. 3) CHECK YOUR GRADE ON 4" WASTW ALONG NORTH WALL. |