Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/02/2004 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 10/28/2004 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SECURE A/C DISCONNECT ON ROOF FROM ROTATING 2) INSTALL TRAP AND VENT A/C CONDENSATE 3) CONDENSATE A/C TO TERMINATE NEAR GROUND LEVEL IN AREA CAPABLE OF DRAINING AWAY 4) A/C CONDENSATE INCORRECTLY COLOR CODED 5) INSTALL ADDITIONAL SUPPORT GAS PIPING ON ROOF 6) INSTALL ANTI SIPHON HOSE BIBS 7) CUT SEWER CLEANOUTS TO GRADE 8) COMPLETE H20 HEATER INSTALL 9) MARK SERVICE PANEL 10) INSTALL PERMANENT ADDRESS NUMBERS ON HOUSE 11) INSTALL DISHWASHER 12) STOPPED INSPECTION. COMPLETE ALL TRADES AND RECALL |