Permit: T03CM05920

Parcel: 117190570


Addresses:

456 S OTERO AV

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/14/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/02/2004 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*/ 1) MAIN HOUSE OK, CASITA PENDING
05/28/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) MASONRY ADDITIONS ON TOP OF EXISTING WALLS HAVE BEEN ADDED-NOT ON PLAN. PROVIDE CITY APPROVED DETAIL OF CMU TO BRICK CONNECTION AT MASTER BEDROOM 2) PORCH LEDGER REQUIRES POSITIVE LATTERAL CONNECTION TO FRAME 8/A6 SHOWS LAG BOLTS 3) HOUSE ADDITION FOUNDATION IS NOT PER APPROVED PLAN BATHROOM HAS WINDOW LESS THAN 3 FT TO PROPERTY LINE 4) ROOF NAIL IS PER CODE BUT HOUSE IS NOT PROPERLY SITED AT BATHROOM FOOTING 5) REVISE PLAN FOR M/BR
05/18/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) FIREBLOCK AT DOUBLE WALLS AT CEILING 2) SUBMIT APPROVED DRAWINGS FOR REAR ROOM ROOF STRUCTURE AND CMU ADDED TO EXISTING CMU WALL 3) NO ACCESS TO ROOF