Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM05920
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/14/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
06/02/2004 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :*/ 1) MAIN HOUSE OK, CASITA PENDING | |
05/28/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) MASONRY ADDITIONS ON TOP OF EXISTING WALLS HAVE BEEN ADDED-NOT ON PLAN. PROVIDE CITY APPROVED DETAIL OF CMU TO BRICK CONNECTION AT MASTER BEDROOM 2) PORCH LEDGER REQUIRES POSITIVE LATTERAL CONNECTION TO FRAME 8/A6 SHOWS LAG BOLTS 3) HOUSE ADDITION FOUNDATION IS NOT PER APPROVED PLAN BATHROOM HAS WINDOW LESS THAN 3 FT TO PROPERTY LINE 4) ROOF NAIL IS PER CODE BUT HOUSE IS NOT PROPERLY SITED AT BATHROOM FOOTING 5) REVISE PLAN FOR M/BR |
|
05/18/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) FIREBLOCK AT DOUBLE WALLS AT CEILING 2) SUBMIT APPROVED DRAWINGS FOR REAR ROOM ROOF STRUCTURE AND CMU ADDED TO EXISTING CMU WALL 3) NO ACCESS TO ROOF |