Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/05/2004 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 04/02/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NEED NUT/WASHER AT S.W. GARAGE 2) SHIM PATIO TRIMMER |
| 03/31/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NEED RED HEAD AND WASHER/NUT ON A.B. AT SOUTH EAST AND SOUTH WEST GARAGE 2) ADD DRYER DUCT BOX AT BOTTOM 3) NEED KINGS UNDER EAST END OF GIRDER TRUSS 4) PROTECT WIRES FROM METAL TRUSS GUSSETS 5) FHA STRAP MASTER BATH PLUMBING STUDS 6) SEAL MESH FLASHING ON NORTH WALL 7) NEED DOUBLE TRIMMERS AT PATIO DOOR 8) SHIM HEADERS WHERE NEEDED 9) NEED SMOKEY IN N.W. BED 10) NEED DWV |