Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 03/02/2004 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000*/ 1) ABS DWV THRU ROOF OK. 2) PEX OK. 3) TUBS OK. 4) CLOSET FLANGES OK. 5) OK TO COVER ALL AREAS. / REVISE PLAN FOR BATHROOM LAYOUT. |
| 03/01/2004 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 03/01/2004 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) NOT READY FOR INSPECTION |
| 02/23/2004 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) WASTE AND VENT TO BE WATER OR AIR TESTED THRU ROOF. 2) ABS TO BE SUPPORTED AT 4' INTERVALS ON HORIZONTAL. 3) TUB AND SHOEWER VALVE TO BE SUPPORTED PROPERLY. 4) WHERE PEX H20 CONTACTS EACH OTHER MUST HAVE INSULATION OR SEPERATION. 5) INSTALL WALL CLEAN OUT AT LOCATIONS SHOWN. 6) PLEASE INSTALL PER PLAN OR HAVE CITY APPROVED PLAN SHOWING INSTALLATION. THIS MAY NOT BE A COMPLETE LIST. |
| 02/19/2004 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000* |