Permit: T03CM05873

Parcel: 12218162B


Addresses:

1375 N ALVERNON WY

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
07/15/2004 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*/ 1) OK WALLS
07/14/2004 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*/ 1) FINISH PREVIOUS ITEMS
07/12/2004 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) PROTECT M/C CABLE IN SHALLOW STUDS 300.4 2) PROTECT PVC CONDUITS STUBS AT BASE PLATES 3) SUPPORT M/C CABLE WITHIN 12" OF EXHAUST FANS 4) SUPPORT PVC BELOW SUB PANEL 5) TIGHTEN LOOSE CONDUIT FITTINGS-PVC TO CONDUIT TO ? 6) OK INTERIOR WALLS EXCEPT AS NOTED