Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 02/02/2004 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 01/22/2004 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ PLEASE PROVIDE GAS PERMIT. |
| 01/21/2004 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) ABS DWV THRU ROOF OK. CONTRACTOR TO INSURE WATER TIGHTNINGS - WET FROM RAIN? 2) COPPER WATER PIPING OK. CLOSET FLANGES OK. 3) OK TO COVER ALL AREAS. 4) WATER HEATER NOT INSTALLED PER 94 UPC. SEE 511.2 94 UPC - LOCATION. EXPANSION TANK TO BE SUPPORTED. DRAIN PAN REDUCING FROM 1" TO 3/4" CONSIDERED AN OBSTRUCTION. |
| 01/20/2004 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 01/16/2004 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
1) ABS UNDERGROUND OK - INSTALLED PER REVISED APPROVED PLAN. 2) OK TO COVER. 3) CONNECTION TO EXISTING OK. |