Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM05817
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/02/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
01/30/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) NAIL OFF ALL BLACK MARKS ON ROOF 2) NEED TRUSS DRAWINGS-CHECK FRONT HIP LAYOUT 3) NEED HANGER HARDWARE AT HIP BOTTOM CHORDS THREE TRUSSES 4) NAIL GARAGE SHEAR WALL TOP PLATE TO ROOF 5) SHIM ALL 3PT BEARING TRUSSES 6) EXTERIOR WALL, SHEAR #3 IS A BLOCKED SHEAR (DRYWALL) MID HEIGHT INSTALL BLOCKS |