Permit: T03CM05808

Parcel: 140373810


Addresses:

7059 S PLOVER CT

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/14/2006 FRAMING Approved
01/26/2005 FRAMING Partial Approval IVRS - Inspection :*
1) PENDING WATER HEATER RELOCATION
03/01/2004 FRAMING Denied IVRS - Inspection 0935*/ 1) CHECK FOR FIRE BLOCKING 2) WATER HEATER FLUE CHASE NOT ? 2ND FLOOR 3) OUTLET MUST BE WITHIN 36" FROM WASH BASIN IN MASTER BATH 4) ROMEX CROSSING THROUGH ATTIC ACCESS 5) NAIL PROTECT ALL ELECTRICAL WITHIN 1 1/4" FROM EDGE OF STUD 6) ROMEX NOT ALLOWED TO BE NAILED ON IT'S SIDE 7) NAIL PROTECT ALL PLUMBING WITHIN 1 1/2" FROM EDGE OF STUD 8) POSSIBLE LEAK AT LAUNDRY ROOM 9) HOLDOWNS NOT NAILED AND STUD MISSING 10) INSULATE BEHIND TUBS 11) FIRE BLOCK AT STAIR LANDING TO HIGH
02/27/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) NO PLANS/PERMIT ON SITE 2) LATH NOT COMPLETE 3) NO FLASHING AT PATIO CONNECTION TO HOUSE 4) GROUND METAL BOXES EXTERIOR 5) PROVIDE EPOXY AND SAW CUT OF CONCRETE AT GARAGE SPECIAL INSPECTION TO INCLUDE VERIFICATION OF 3000 ASI CONCRETE USED TO PATCH OR AS PER PLAN REQUIREMENT 6) STOPPED INSPECTION-WILL REINSPECT
02/20/2004 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) CANCELLED ON SITE BY JOHN SERBIN