Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T03CM05788
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/15/2004 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :*APPROVED.*IN FUTURE DO NOT BEND BACK OR REMOVE BOX CABLE CLAMPS. | |
06/30/2004 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*/ 1) ALL SPLICES TO BE ACCESSIBLE 2) SUPPORT NM CABLE WITHIN 12" OF BOXES-EXHAUST FANS, ? 3) BOX ? TO BE USED ON BOXES OTHER THAN SINGLE GANG 4) SUPPORT CABLES ABOVE PANEL AND USE CONNECTORS LISTED FOR CONDUCTORS 5) SUPPORT CONDUIT BELOW PANEL AND TIGHT 6) YOU HAVE BOX OVERFILL 7) MAINTAIN BOX SEPERATION IN FIRE WALL 8) PROTECT CABLES AT STUDS 9) OUTLETS TO BE SPLICED AS PER CODE | |
04/27/2004 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NO ONE ON SITE, CALLED CONTRACTOR LEFT MESSAGE. UNITS STILL FENCED OFF APPEARS NO REPAIRS HAVE BEEN MADE |