Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T03CM05776
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/10/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :*/ 1) CORRECTIONS MADE OK 2) CLOSET FLANGE OK 3) OK TO COVER ALL AREAS | |
08/05/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*/ 1) PEACH PROP DBS BSH BUILDERS 2) PLEASE HAVE PLUMBER ON SITE AT TIME OF NEXT INSPECTION 3) ABS DWV THROUGH ROOF OK TO COVER SUBJECT TO APPROVED PLAN 4) COPPER OK TO COVER SUBJECT TO ARCHITECT LETTER ON MATERIAL TYPE 5) SHOWER VALVES HAVE INTEGRAL STOP 6) NEED TO SEE CLOSET FLANGES | |
08/04/2004 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection :CHANGE IN DIRECTION NEEDS TO BE SWEEP POST UNIT NUMBERS NEED TO SEE CLOSET FLANGES |
|
08/02/2004 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SEE NOTES FROM 7/27/04 2) PROVIDE LETTER STAMPED FROM ENGINEER OR ARCH FOR T/M IN PLACE OF T/L COPPER IN BLDG 3) INSTALL VENT FITTINGS CORRECTLY 4) SUPPORT PIPING PROPERLY IN WALLS AND AT MID-SPAN |
|
07/27/2004 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection :DENIED. (1) WATER TEST OR AIR TEST ALL PIPIING. (2) INSTALL PER YOUR APPROVED PLAN. | |
07/23/2004 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection :COPPER LINES CANNOT BE IN CONTACT WITH GALVANIZED STUBS |