Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/25/2004 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 03/22/2004 |
FRAMING |
|
Cancelled |
IVRS - Ri canceled |
| 03/18/2004 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) OVERNOTCHED DOUBLE TOP 2) FIRE BLOCK MECH CHSSE 2ND FLOOR AND REPAIR DUCT 3) NAIL PROTECT DUCT AT MECH CHASE |
| 03/17/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* SEE LAST INSP. |
| 03/15/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) HOLD DOWN MISSING NUT. 2) FIRE BLOCKS MISSING THROUGHOUT. 3) FIRE BLOCK MECH. CHASES. 4) NAIL PROTECT ELECTRICAL WITHIN 1¼ FROM EDGE OF STUD. 5) SECURE GAS LINE ABOVE LAUNDRY ROOM. 6) CHECK DWV'S FOR PROPER TEST ENTIRE HOUSE. 7) NAIL PROTECT PLBG WITHIN 1½ FROM EDGE OF STUD. 8) SECURE ROMEX WITHIN 8" FROM BOX. |