Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM05741

Parcel: 138133170

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
03/29/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
02/20/2004 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) OK TO DRY IN 2) ALTERNATE HOLDOWN REQUIRED AT NORTH END WEST WALL
02/19/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) SPHD8 ON WALL BROKEN OUT OF SLAB NORTH END OF SHEAR WALL. PROVIDE ALTERNATE HOLDOWN 2) DOUBLE STUD POST GIRDER TRUSS TO GROUND 2 ENDS 3) STRAP WEST WALL