Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
05/20/2004 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection :*/ OK FOR SHEET ROCK.
04/01/2004 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection 0999*/ DRYER VENT INSTALLED WITH CRIMPED ENDS IN WRONG DIRECTION. EXTEND BATHROOM EXHAUST DUCT UP INTO T-TOP IN LAUNDRY ROOM. PROVIDE SCREEN IN ALL T-TOPS EXCEPT DRYER VENT. PROVIDE A SCREW WHERE EXHAUST DUCTS CONNECTS TO FAN. INSTALL CONDENSATE DRAIN. INSULATE ALL SIDEWALL REGISTER BOXES. PROVIDE BACKING ON ALL BOXES. INSULATION ON T-WYES AND REGISTER BOXES MUST HAVE A VAPOR BARRIER. PROVIDE APPROVED PLANS TO BE ON SITE AT ALL TIMES. RECALL FOR INSP. PRIOR TO ANY SHEET ROCK.