Permit: T03CM05713

Parcel: 13216600A


Addresses:

4004 S PARK AV 02


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T03CM05713

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
04/26/2004 PLUMBING - FINAL Approved IVRS - Inspection :*/ 1) ALL CORRECTIONS HAVE BEEN MADE
04/19/2004 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) SEE NOTE #2 AS REQUESTED FROM PREVIOUS INSP. 2) PROVIDE VACUUM BREAKERS AT HOSE BIB DRAINS.
04/14/2004 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) SEE NOTE #2 AS REQUESTED FROM PREVIOUS INSP. 2) CAN NOT HAVE UNION IN GAS LINE. MUST BE RIGHT/LEFT HAND NIPPLE. 3) MUST HAVE ACCESS TO T&P DRAIN TERMINATION POINT.
04/07/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ T & P FROM WTR HTR TO BE BTU RATED FOR HTR. THIS MAY NOT BE A COMPLETE LIST.
03/19/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST IS OK 2) NOTE: NO APPROVED PLANS ON SITE 3) MUST SEE FINAL CONNECTION TO EXISTING GAS LINE AND WATER SUPPLY