Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ABOVE CEILING
Permit Number - T03CM05709
Inspection Description - PLUMBING - ABOVE CEILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/12/2004 | PLUMBING - ABOVE CEILING | Approved | IVRS - Inspection 0000* | |
01/06/2004 | PLUMBING - ABOVE CEILING | Not ready for Inspection | IVRS - Inspection 0000* | |
01/05/2004 | PLUMBING - ABOVE CEILING | Denied | IVRS - Inspection 0999*/ 1) A TRAP ARM MAY ONLY CHANGE DIRECTION 90o WITHOUT A CLEAN OUT. 2) ONLY ONE TRAP ON A TRAP ARM. SUNTEE MAY NOT LAY ON ITS SIDE. 3) SUPPORT COPPER. |