Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03CM05709

Parcel: 10709049B


Addresses:

2445 N ORACLE RD


Inspection Status: Approved

Inspection History: PLUMBING - ABOVE CEILING

Permit Number - T03CM05709

Inspection Description - PLUMBING - ABOVE CEILING

Inspection Status - Approved

Date Description Inspector Results Comments
03/12/2004 PLUMBING - ABOVE CEILING Approved IVRS - Inspection 0000*
01/06/2004 PLUMBING - ABOVE CEILING Not ready for Inspection IVRS - Inspection 0000*
01/05/2004 PLUMBING - ABOVE CEILING Denied IVRS - Inspection 0999*/ 1) A TRAP ARM MAY ONLY CHANGE DIRECTION 90o WITHOUT A CLEAN OUT. 2) ONLY ONE TRAP ON A TRAP ARM. SUNTEE MAY NOT LAY ON ITS SIDE. 3) SUPPORT COPPER.