Permit: T03CM05700

Parcel: 123023050


Addresses:

2502 E HAMPTON ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
10/19/2004 BUILDING - FINAL Approved IVRS - Inspection :*
10/12/2004 BUILDING - FINAL Partial Approval IVRS - Inspection :*/ 1) KITCHEN GFCI OUTLETS MUST BE 2-20A CIRCUITS 2) OUTLET NEAR SINK IN GARAGE MUST BE GFCI PROTECTED 3) A/C OVERFUSED-40 AMP MAX 4) A/C DISCONNECT NOT PERMITTED BEHIND UNIT 5) MULTIPLE WIRES UNDER SINGLE LUG OF BREAKER NOT PERMITTED 6) T & P LINE OF WH MUST FACE DOWN 7) PARTIAL APPROVAL PENDING ELECTRICAL CORRECTIONS 8) REVISE PLAN TO AS-BUILT AND OBTAIN CITY APPROVAL