Permit: T03CM05700

Parcel: 123023050


Addresses:

2502 E HAMPTON ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/06/2004 FRAMING Approved IVRS - Inspection :*
08/05/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) PARTIAL PENDING GIRDER HANGER INSTALL 2) INSTALL SHOWER UNIT 3) TEST REQUIRED ON DWV SYSTEM
08/02/2004 FRAMING Partial Approval IVRS - Inspection :USE CORRECT HANGER AT GIRDER TO GIRDER CONNECTION (HUS28-2 TF) 2, 433 LBS ON CONNECTION HUS 28-2 WON'T WORK must be a top flange
at hip connection at garage use a dbl hanger those connections
broken web, in truss above hallway marked on floor
NEED PERMANENT CAP AT END OF FLEX DUCT NEAR GARAGE