Permit: T03CM05693

Parcel: 10604299E

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
04/13/2004 PLUMBING - INTERMEDIATE Approved
02/25/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/ 1) OK TO COVER WALLS 2) PLEASE PROVIDE APPROVED WASHER FOR SHOWER PAN FOR GLASS WASH AREAR 3) DRIP PAN LINE NOT INSTALLED
02/20/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*/ 1) WILL REQUIRE C.O. AT EWC - A TRAP ARM MAY ONLY CHANGE DIRECTION 90o WITHOUT ADDITIONAL C.O. 2) A TRAP ARM MAY NOT CHANGE SIZE. A LAVATORY IS LIMITED TO A 1½" TRAP ARM AS TRAP IS TO BE SAME SIZE AT TRAP ARM AND TRAP MAY ONLY BE ONE SIZE LARGER THAN TAILPIECE. 3) CONDENSATE DRAIN MAY NOT BE CONNECTED TO A SINK TAILPIECE. 4) SEE 511.2 LOCATION OF WATER HTR ABOVE 8'. 5) WHAT ABOUT PANS AND PAN DRAINS FOR WTR HTR?