Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 04/13/2004 |
PLUMBING - INTERMEDIATE |
|
Approved |
|
| 02/25/2004 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) OK TO COVER WALLS 2) PLEASE PROVIDE APPROVED WASHER FOR SHOWER PAN FOR GLASS WASH AREAR 3) DRIP PAN LINE NOT INSTALLED |
| 02/20/2004 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) WILL REQUIRE C.O. AT EWC - A TRAP ARM MAY ONLY CHANGE DIRECTION 90o WITHOUT ADDITIONAL C.O. 2) A TRAP ARM MAY NOT CHANGE SIZE. A LAVATORY IS LIMITED TO A 1½" TRAP ARM AS TRAP IS TO BE SAME SIZE AT TRAP ARM AND TRAP MAY ONLY BE ONE SIZE LARGER THAN TAILPIECE. 3) CONDENSATE DRAIN MAY NOT BE CONNECTED TO A SINK TAILPIECE. 4) SEE 511.2 LOCATION OF WATER HTR ABOVE 8'. 5) WHAT ABOUT PANS AND PAN DRAINS FOR WTR HTR? |