Date Description Inspector Results Comments
03/24/2004 FRAMING Approved IVRS - Inspection 0000*
03/23/2004 FRAMING Partial Approval IVRS - Inspection 0000*
03/22/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) SOLID BLOCK AND NAIL CRIPPLE WALLS AT ENTRY PER DETAIL 2) INSTALL DETAIL 7, DT1 AT ENTRY 3) TEST WASTE 4) INSTALL POST AT GARAGE GIRDER 5) REVISE AND OBTAIN APPROVAL AT GARAGE SHEAR. DOES NOT MATCH PLAN 5) FIRE STOP FURNACE PLATFORM 6) COMPLETE HOLDOWN INSTALLATION