Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM05686
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/24/2004 | FRAMING | Approved | IVRS - Inspection 0000* | |
03/23/2004 | FRAMING | Partial Approval | IVRS - Inspection 0000* | |
03/22/2004 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) SOLID BLOCK AND NAIL CRIPPLE WALLS AT ENTRY PER DETAIL 2) INSTALL DETAIL 7, DT1 AT ENTRY 3) TEST WASTE 4) INSTALL POST AT GARAGE GIRDER 5) REVISE AND OBTAIN APPROVAL AT GARAGE SHEAR. DOES NOT MATCH PLAN 5) FIRE STOP FURNACE PLATFORM 6) COMPLETE HOLDOWN INSTALLATION |