Permit: T03CM05674

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T03CM05674

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
03/01/2005 PLUMBING - GAS PRESSURE TEST Approved
10/29/2004 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*/PLEASE NOTE COMPLETE GAS LINES TO FIRE PLACE & CALL FOR INSP
07/06/2004 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*/ 1) 30 PSI AIR TEST ON 1 1/4 FROM METER TO 1/2" AT (8) FIRE PLACE LOCATIONS 9" ABOVE FINISH FLOOR IN WALL 2) SECURE ALL DROPS PROPERLY 3) APPROVED GAS VALVES SHUT OFF OUTSIDE OF HEARTH WITHIN 4' OF HEARTH REQUIRED PER 94 UPC 4) THIS PARTIAL FOR OVERNOTCHED PIPING, AND WILL REQUIRE RETEST
07/02/2004 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
07/01/2004 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*