Permit: T03CM05626

Parcel: 140373990


Addresses:

6205 E STONECHAT DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/29/2004 FRAMING Approved IVRS - Inspection :*
04/28/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
04/26/2004 FRAMING Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspection. Double refee. Holdowns nuts not tightened
04/23/2004 FRAMING Partial Approval IVRS - Inspection :
See detailed listing on site.| 999*/ 1) FRAMING WILL BE APPROVED WHEN HD NUTS ARE TIGHTENED AND ELECTRICAL BOX INSTALLED AT STAIR RAIL AREA, STAIR RAIL MODIFIED
04/22/2004 FRAMING Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspection. HOLDOWNS, NUTS NOT INSTALLED
04/21/2004 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) PENDING HD'S NUTS
04/20/2004 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) FRAMING WILL BE APPROVED WHEN ALL TRADES ARE COMPLETE 2) FAU FLUE NOT CONNECTED 3) MECHANICAL FLEX NOT COMPLETE 4) SECONDARY PAN NOT INSTALLED CONDENSATE LINES NOT INSTALLED 5) SEDIMEN TRAP REMOVED FROM GAS LINE AT FAU, RETEST GAS LINE 6) BLOCK OUT MECH IN LIVING AND POWDER ROM 7) PROVIDE MECH PLAN FOR FLEX CONNECTION INTO POWDER ROOM 8) SEE #4, 6 AND 8 INSPECTION DATED 4/14/04
04/16/2004 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) PROVIDE 1" CLEARANCE FROM COMBUSTIBLES AT WATER HEATER FLUE 2) SECURE ELECTRIC WIRES WITHIN 8" FROM BOX AND NAIL PROTECT THROUGHOUT HOUSE 3) SEAL WATER HEATER FLUE PENETRATIONS 4) SEE INSPECTION DATED 4/14/04
04/14/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) FIRE BLOCK MISISNG AT WATER HEATER STAND 2) GAS LINE IN LAUNDRY ROOM RESTING ON ROMEX 3) BLOCK OUT DRYER VENT 4) HD UNDER STAIRS MISSING BOLT/NUT 5) MOVE ELECTRICAL WIRES AWAY FROM GUSSETT PLATES 6) BLOCK OUT MECHANICAL LIVING ROOM 7) MOVE DUCT WORK AWAY FROM GUSSETT PLATES 8) BLOCK OUT MECH IN POWDER ROOM 9) WILL RE-CHECK ENTIRE HOUSE