Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/23/2004 | FRAMING | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 04/22/2004 | FRAMING | Partial Approval | IVRS - Inspection : See detailed listing on site.| 999*/ 1) HOLDOWNS NOT INSTALLED |
|
| 04/21/2004 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) FRAMING OK-WILL APPROVE PENDING HOLDOWNS | |
| 04/20/2004 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) DUCT AT POWDER ROOM (FLEX NOT PER PLAN) 2) SEAL CHASE AT WATER HEATER FLUE 1ST AND 2ND FLOOR 3) HD'S NOT NAILED AND BOLT MISSING 4) RAT RUN AT FLOOR TRUSSES CUT | |
| 04/19/2004 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) MOVE WIRES AWAY FROM WATER HEATER FLU 2) PLUMBING OUT OF WALL AT LAUNDRY ROOM 3) HOLDOWNS MISSING BOLTS 4) BLOCKS AT STRINGERS NOT PER CODE 5) SEAL CHASE PENETRATIONS FOR B-VENT AND REMOVE ALL WOOD SHAVINGS AWAY FROM B-VENT 6) SEE PREVIOUS INSPECTION FOR ITEMS NOT DONE | |
| 04/16/2004 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) LEAK AT TUB 2ND FLOOR ABOVE WATER HEATER 2) WATER LINE OK 3) NAIL LSL W/16D'S 4 ON CENTER IN GARAGE 4) PLUMBING OUT OF WALL AT WATER HEATER AREA 5) HOLDOWNS MISSING AT GARAGE SHEAR WALL 6) NO A/C IN POWDER ROOM 7) STRAPS AT ENTRY MISSING NAILS 8) LEDGER AT ENTRY NOT NAILED 9) FIRE BLOCKS AT STAIRS NOT PER CODE 10) SEAL OPENINGS AT WATER HEATER CHASE 11) NAIL PROTECT ELECTRIC AND SECURE WITHIN 8" FROM BOX 12) BLOCK MECH IN DINING ROOM | |
| 04/14/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* |