Permit: T03CM05601

Parcel: 129053900


Addresses:

2014 E EASTLAND ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/02/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
792-CITY
791-5550
10/30/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
SEE NOTE #1 FROM 10/24/06 INSPECTION
PROVIDE OPEN FRONT STOOL SEAT & PROVIDE BRASS NIPPLES
OR DIELECTRIC PROTECTION AT WATER HEATER. CANNOT GO COPPER TO GALV.
10/24/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE VACUUM BREAKERS AT ALL HOSE BIBBS
2. INSTALL EXPANSION TANK AT WATER HEATER & SECURE PROPERLY.
3. WATER HEATER REQUIRES DRIP PAN & FULL SIZE DRAIN.
4. STOOL REQUIRES FLUSH HANDLE TO WIDE SIDE OF ROOM