Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM05586
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/17/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
02/11/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*1) NAIL ROOF TO LEDGER 8ds 6" O.C. 2) NEED TO CROSS BRACE TRUSSES AT FRONT; REMOVE DAMAGED LUMBER TOP TO BOTTOM; NAILS IN SHEAR ONE PIECE 3) BREAK GAMBLE ENDS AT FLAT 2X4s TRUSS 4) FRONT GABLE FLAT VERTICLE 2X4 MISSING 16" O.C. 5) MORE NAILS LEDGER TO STUD. OK TO DRY IN, NOT LOAD 6) REMOVE ALL OLD LUMBER USED FOR BRACING END WALL KICKERS |