Inspection History Details
Inspection Status: Partial Approval
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM05585
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Partial Approval
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/27/2004 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000* | |
02/27/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
02/24/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000* | |
02/18/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) SEE LAST INSPECTION | |
02/13/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) NAIL OSB TO TRUSS GARAGE HIP, MARKED 2) EAST SIDE OF GARAGE HEADER, SUPPORT, BOTTOM PLATE LOOSE 3) OSB ROOF DECK CUT SHORT DOESN'T TIE TRUSSES TO LEDGER GARAGE 4) BRACE FLAT 2 X 4 AT MID POINT END GABLES 5) TWO NAILS IN EACH (WIND BRACE METAL) TOP AND BOTTOM PLATE 6) ADD ONE WIND BRACE WALL WEST WALL EACH CORNER AND 25" ON CENTER 7) SHEAR PANELS, NAILING AND HIP RAFTER CUT 8) SHEAR PANELS WEST SIDE NOT INSTALLED CORRECTLY 9) LARGE CROSS BRACES, NOT NAILED OFF AT TOP AND BOTTOM PTS. 10) HOLDOWNS WRONG SIZE HOLES, DON'T USE 11) MISSED NAILING REAR PORCH LEDGER TO WALL |