Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/03/2004 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 01/29/2004 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) NAIL OFF ALL BLACK MARKS ON ROOF 2) GARAGE TO HOUSE CRICKET NEEDS SUPPORT 24" ON CENTER 3) BRACE LONG FLAT 2 X 4 AT GABLES 4) NEED 3 WIND BRACES ON SOUTH WALL 5) AT FRONT ENTRY FINISH 45 DEGREE TOP PLATE 6) NAIL BOTTOM CHORD TO FLAT 2 X REAR GABLE ALSO GARAGE TO HOUSE TRUSS BOTTOM CHORDS 7) WIND BRACE CUT IN HALF AND NORTH WALL 8) DON'T USE 10D TECS IN HANGER=16D SINKER |
| 01/27/2004 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) CARPENTERS STILL WORKING |