Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T03CM05570

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
02/03/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
01/30/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) INSTALL WIND BRACE REAR WALL 2) INSTALL ONE SHEAR PANEL LAST BAY, AT REAR SHEAR GABLE BAY 3) MISSED VERT. SHEAR NAILING REAR SHEAR, EAST-WEST WALL 4) SHEAR WALLS, SW5, EACH SIDE OF REAR SLIDER. TRANFERS CONNECTION, INSTALL PER 17/D1