Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 04/27/2005 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection :* |
| 04/26/2005 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :* 2" FLOOR SI?? AT EXTERIOR ( SOUTH CENTER) VENDING MACHINE AREA WITH TRAP PRIMER OK. |
| 04/19/2005 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection :* |
| 03/15/2005 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :* WATER TEST & VENT THRU ROOF EMPLOYEE REST ROOMS & LOUNGE & MOP SINK OK. H20 ?? AREA AIR TEST OK. 1) NEED TO SEE INSTALL OF EY? WASH/ SHOWER. |
| 03/14/2005 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :* (4) 3" VENTS THRU ROOF ( CENTER STORE AREA) DISPLAY CASED WATER TEST OK |
| 03/09/2005 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :* THRU ROOF WATER TEST WASTE & VENT PUBLIC RESTROOMS, FAMILY RESTROOM, PHARMACY AND MEZZANINE ABOVE OK H20 ALSO OK. 3" VENT SOUTH EAST CORNER FOR COMBINATION WASTE & VENT SYSTEM WATER TEST THRU ROOF OK. |
| 03/07/2005 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :* PARTIAL APPROVAL H20 PIPING PUBLIC RESTROOMS, FAMILY REST ROOM, PHARMACY, STUBBED OVER TO OUTSIDE VENDING OK |
| 02/28/2005 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :* WATER TEST WASTE & VENT THRU ROOF AT PHARMACY SINK OK 100 PSI AIR TEST 1/2" HOT & COLD FOR SAME OK PARTIAL APPROVAL |
| 02/15/2005 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :* 3" VENT FOR COMBINATION WASTE & VENT AT NORTH WEST END WATER TEST OK. 2" VENT FROM FLOOR SINK FOR AHU? AT NORTH H CENTER WATER TEST THRU ROOF OK |
| 02/14/2005 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :* PARTIAL APPROVAL 2" VENT FOR FLOOR SINK IN MEAT PREP, WASTE & VENT THRU ROOF PL3-20 SINK GREASE WASTE & SANITARY WASTE, AND 2 ?? FROM FLOOR DRAINS IN MEAT PREP WATER TEST OK. 80 PSI H20 PIPING AIR TEST ALL ATEAS EXCEPT REST ROOMS, WATER HEATER AREA OK |
| 02/11/2005 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :* 2'' FLOOR SINK FOR SOUTH ?? OK IN WALL & OVERHEARD WASTE & VENT & H20 PIPING WATERS AIR TEST OK FOR PRODUCE PROP. DELI PROP, DINING & BAKERY OK |
| 02/10/2005 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :* |
| 02/08/2005 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :* WATER TEST THRU ROOF HAND SINK IN ?? COOLER AND 3" VENT THRU ROOF FOR 3" ?? SAME WALL OK 1/2" HOT & COLD H20 TO HAND SINK IN MEAT COOLER OK WATER TEST WASTE & VENT UNDERGROUND FOR BROA? ROOM AND 4" STUB TO WEST APP. 15' FOR EVAP CONDENSER FLOOR SINK OK. NEED REVISED PLUMBING PLAN FOR ADDITION OF SINK IN NORTH EAST CORNER. |