Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T03CM05561
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/27/2005 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* REVISED CITY APPROVED PLAN ON SITE. | |
| 03/29/2005 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
| 02/17/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* PARTIAL APPROVAL 4" GREASE WASTE TO GREASE TRAP WATER TEST OK. 4'' DRAIN FROM GREASE TRAP TO SANITARY SEWER WATER TEST OK. 3" VENT FROM GREASE TRAP WATER TEST TO 2' ABOVE FINISH FLOOR OK. 1) PROVIDE WATER TEST ON GREASE TRAP DUE TO DAMAGE TO INLET OF TANK. 4" HCS CONNECTION AT NORTHEAST END OF BUILDING OK | |
| 02/14/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* WATER HEATER 4" FLOOR SINK DRAIN AT COOLING TOWER OK ( UNDERGROUND) | |
| 02/11/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
| 02/10/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
| 02/08/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
| 01/26/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* PARTIAL APPROVAL TRENCH DRAINS IN NORTH WEST ?? PER PLAN OK | |
| 01/24/2005 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
| 01/21/2005 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
| 01/19/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* ISTALL 2-3" FLOOR DRAINS. PER YOUR APPROVED PLAN FOR TRENCH DRAIN AT DAIRY COOLER OR HAVE REVISED CITY APPROVED PLAN. |
|
| 01/12/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* WATER TEST TRENCH DRAIN AT ?? BOX & PIPE WRAPS THIS AREAS OK | |
| 12/29/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*/COMBINATION WASTE & VENT ON NORTH WEST SECTION UNDERGROUND WATER TEST OR PER HIGHLIGHTED & INITIALED PLAN ON SITE. 1) WILL REQUIRE CITY APPROVED REVISED PLAN OF ALL RED LINES AND ADDITIONAL FIXTURES | |
| 12/21/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*/WATER TEST UNDERGROUND ONLY SOUTH WEST 4" SANITARY DRAIN FOR SF-SINK, QWC, SINGLE RESTROOM, AND (2) GANG REST ROOM WITH 2" DRAIN CONTINUATION FOR FLOOR SINK TO BE INSTALLED AT LATER DATE PER HIGHLIGHTED & INITALED PLAN IN TRAILER. | |
| 12/13/2004 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
| 12/13/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* WATER TEST UNDERGROUND GREASE WASTE & SANITARY WASTE PER HIGHTLIGHTED AND INITALED PLAN PAGE P-2 | |
| 12/09/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*/4" BUILD DRAIN ON WEST END OF BUILDING PER HIGHLIGHTED AND INITALED ON P-2 | |
| 12/08/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*/UNDERGROUND WATER TEST ON WASTE & VENT SHOWN ON REVISED CITY APPROVED PLAN P-2 FER HIGHLIGHTED AND INITALED | |
| 12/03/2004 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 12/02/2004 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :*/ 1) PLEASE HAVE A CITY APPROVED PLAN OF YOUR BLDG ON SITE AT TIME OF INSPECTION |