Permit: T03CM05561

Parcel: 11415008V


Addresses:

8080 S HOUGHTON RD


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T03CM05561

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
04/13/2005 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
03/10/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/28/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* 12' WALL AT NE CORNER
02/23/2005 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
02/22/2005 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
02/16/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* TOP OUT @ INFILL OK
02/15/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* LINE INFILL TO ROOF LINE
02/14/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* PARTIAL WEST OPENING
02/11/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/10/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/08/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* NOT READY REINFORCED MASONRY
02/03/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* 4' @ INFILL LINE 1
01/28/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* TOP AT FRONT POPOUTS OK
01/26/2005 REINFORCED MASONRY PRE-GROUT Partial Approval SEE NOTES 1-24
01/24/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* FRONT POP OUTS TO 12'
01/19/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* TOP PERIMETER EXCEPT INFILL
01/12/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*TOP LINE 5/F-G & 24' LINE G/5-5.5; 4' LINE 7/F-G
01/11/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* 24' LINE B/F-G; 20' LINE G/B-7; 4' LINE G/7-8
01/10/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*24'LINE F/15
01/06/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*/20' OK WHEN SPEC INSP CONFIRMS LINE F
01/05/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*/10' LINE F/1-16 OK TO GROUT
01/03/2005 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*12' LINE F/3-5.5
12/29/2004 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
12/28/2004 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 4' AT G/5-6; 4' AT 6/F-G; 8' AT F/3-5'; 12' E F/2-3; 8' NORTH WEST CORNER
2) LINE A VARIOUS HEIGHTS NEARING TOP OUT
12/27/2004 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
12/23/2004 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
12/22/2004 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) LINE 1/P-F 24'; TOP LINE A-C, 4' LINE F/2-4.5
12/21/2004 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 4' LINE E-F AND LINE F/1-2, 24' LINE 1 A-C
12/20/2004 REINFORCED MASONRY PRE-GROUT Partial Approval 1) 20' LINE 1; 24' LINE A
12/17/2004 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*/16' LINE 1 A-6.5; 20' LINE A 1-5
12/16/2004 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 12' LINE 1 DES; 16' LINE/AC; 16' LINE A 1-4, 20' LINE A 4.5-5.5; TOP LINE A G-7, 8-10, LINE 10 A AND F, LINE F 7-10
12/15/2004 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*/8' LINE 1/C-F; 12' LINE 1/A-C; 16' LINE A/2-5
12/14/2004 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*8' LINE 1/A-C; 12' LINE A 1.5-5.5
12/13/2004 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 4' LINE/A-F (MINUS INFILL); 12' LINE A/3.5-5; 20' LINE A/7-8, 24' LINE 10/A-F, 24' LINE F/7-10 AND 24' LINE A/8.5-10
12/10/2004 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*/24' LINE 10 A-F; 24' LINE F 7-10; 16' LINE A/7-8
12/09/2004 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) P-12' LINE A/5-6, 20' LINE F/7-10
12/08/2004 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) LINE A 65-3.5 E8'; 20' LINE 10 A-F, 20' LINE A/8-10
12/03/2004 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
12/02/2004 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :4' LINE 1/A-B; 4' LINE A/1-3; 12' LINE 10/ A-F; 12' LINE A/8.5-10; 8' LINE A/7-8.5
12/01/2004 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*/8' LINE 10 A-F, 8' LINE A 802-10, 8' LINE F NEED CHANNAL IRON
11/29/2004 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*/ 1) 4' LINE A/2-6
11/24/2004 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*/4' LINE F 7-10, LINE A-6-10, LINE 10-A/F
11/23/2004 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*