Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/25/2004 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 03/22/2004 |
FRAMING |
|
Cancelled |
IVRS - Ri canceled |
| 03/18/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 03/17/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) MISSING FLAPPER AT POWDER ROOM EXHAUST FAN 2) FIREBLOCKS MISSING AT STAIRS 3) FIRE BLOCK MECHANICAL CHASE 2ND FLOOR 4) FLOOR AT TOP LANDING NOT FASTENED DOWN |
| 03/15/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) SECURE WTR LINES AT GARAGE. 2) REPLACE BLOWN FIREBLOCK AT WTR HTR PLATFORM. 3) NO TEST ON DWV'S. 4) STRAP DBL TOP PLATE AT KITCHEN. 5) SECURE WTR LINES AT POWDER ROOM. 6) TUBS NOT INSTALLED. 7) FIRE BLOCK MECH. CHASE IN ATTIC. 8) NAIL PROTECT ROMEX UNDER BEDROOM WINDOW 2ND FLOOR SOUTH EAST. 9) FIRE BLOCKS MISSING AT STAIRS. 10) LANDING NOT CLIPPED. |