Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM05518
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/01/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | ||
01/27/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) TRUSS LATERAL BRACE TO BE 2 X 4 NOT 2 X 2, WIND BRACE PROBLEM NOT DONE, SHEAR PANELS NOT NAILED NEED TRUSS DRAWINGS, HANGERS CARRIES 1090 16S, DIFFERENT TYPES OF NAILS USED IN HANGERS | |
01/23/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) SEE LAST INSPECTION | |
01/22/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) NAIL OFF ALL BLACK MARKS ON ROOF 2) NEED ONE MORE WIND BRACE SOUTH WALL 3) WIND BRACE AT NORTH WALL, BENT USE TWO NAILS TO AND BOTTOM PLATE 4) LEAVE TRUSS DRAWINGS, NEED TO VERIFY HANGER LOAD, TYPE GARAGE, WRONG TYPE NAILS 5) BRACE FLAT 2 X 4 GABLE ENDS FOR WIND 6) USE 2 X 4 LATERAL BRACES NOT 2 X 2 |