Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 03/02/2004 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000*/ 1) N/H UNDERGROUND OK. WTR TEST TO TEN FEET OK. 2) OK TO BACKFILL. |
| 03/01/2004 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/ 1) WHERE A VENT CONNECTS TO A HORIZONTAL DRAIN LINES, IT SHALL HAVE IT'S INVERT TAKEN OFF ABOVE THE DRAINAGE CENTER LINE, DOWN STREAM OF THE TRAP BEING SERVED |