Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date |
Description |
Inspector |
Results |
Comments |
| 05/24/2004 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Approved |
IVRS - Inspection :* |
| 05/20/2004 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Not ready for Inspection |
IVRS - Inspection :*/ 1) SECURE ALL P.A.'S 2) HORIZONTAL BARS SPREAD APART AND TIE 3) FTGS TO BE MINIMUM 16" WIDE, 12" BELOW GRADE NORTH WALL GARAGE NOT DEEP ENOUGH 4) ISOLATE STEEL PINS FROM HORIZONTAL BARS, TAPE 5) NO LAP WIRE MESH AT GARAGE FTG. 6) UFER ON 7) NEED SOIL TEST, OR PROVIDE IN WRITING YOU DON'T NEEE ONE 8) HORIZONTAL BARS TO BE SECURED |