Permit: T03CM05457

Parcel: 136328100

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
05/24/2004 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
05/20/2004 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*/ 1) SECURE ALL P.A.'S 2) HORIZONTAL BARS SPREAD APART AND TIE 3) FTGS TO BE MINIMUM 16" WIDE, 12" BELOW GRADE NORTH WALL GARAGE NOT DEEP ENOUGH 4) ISOLATE STEEL PINS FROM HORIZONTAL BARS, TAPE 5) NO LAP WIRE MESH AT GARAGE FTG. 6) UFER ON 7) NEED SOIL TEST, OR PROVIDE IN WRITING YOU DON'T NEEE ONE 8) HORIZONTAL BARS TO BE SECURED