Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/31/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 08/27/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/DENIED-PLANS IN COMPLETE TRADES INCOMPLETE, NOT TO PLAN/CODE STOPPED INSPECTION 1)OVERLAPPED BL. TOP PLATE TO BEAR ON STUDS 2)NEED VERIFICATION O NEW FOOTINGS UNDER NEW BEARING WALLS FRONT LIVING ROOM, DINING ROOM, KITCHEN 3)FIRE BOLCK ALL DROPPED CEILING AREAS 4)FIRE STOP HORIZONTAL MAXIMUM 10' RUNS ON? 2X4 FURRED WALLS 5)NEED FRAMING DRAWINGS FOR FRONT LIVING ROOM-NOT ON PLAN-DINING ROOM,& KITCHEN ALSO 6)INSTALLL SMOKE DETECTOR -LIVING ROOM PER PLAN |
|
| 05/19/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |