Permit: T03CM05386

Parcel: 116124100


Addresses:

1410 W NIAGARA ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/01/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*/ 1) NOTE: CHECK FOR BLOCKS 24" ON CENTER AT ANGLED ROOF EDGES OSB TURNED OPPOSITE TO RAFTERS 2) CHECK CRICKET EXISTING HOUSE, WATER BONDING IN CENTER
05/24/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) ? BEARING PLATE REQUIRED WHEN ROOF SLOPE EXCEEDS 1/4" PER FT 2) MIUST NAIL EXTERIOR SHEATHING HORIZONTALLY ACCESS TOP PLATE UNDER I-? 3) INSTALL NAILS ALL STRUDS-WIND BRACING 4) TJI JOIST FLANGE MUST BEAR FULLY ON TOP PLATE (DO NOT USE WEDGES) (USE ? TOP PLATE) 5) FRONT PORCH INCOMPLETE 6) PLAY CALLS FOR (HIGH POINT) CRICKET ON ROOF TO DRAIN EAST AND WEST (NONE EXISTS) 7) NEED MANUFACTURERS TRUSS DRAWINGS 8) TOO MANY CORRECTIONS TO BE MADE IN I-JOISTS AND ROOF SLOPE CONNOT APPROVE 9) STOPPED INSPECTION CORRECT/COMPLETE ALL TO CODE AND OR PLAN AND RECALL
05/19/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) NAILS/STAPLES SET TO DEEP OR STICKING UP 2) MUST COMPLETE ALL TRADES THEN RECALL FOR INTERMEDIATE INSPECTIONS ALSO 3) STOPPED INSPECTION