Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM05385
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/30/2004 | FRAMING | Approved | IVRS - Inspection 0000* | |
03/25/2004 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) NO TEST DWV 2) SECURE ROMEX KITCHEN CEILING 3) CHECK PREVIOUS LIST | |
03/19/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) FROM LAST INSPECTION ITEMS NOT CORRECTED 2) PEX AT REAR BATH CAN LIGHT 3) BACKING IN KITCHEN | |
03/16/2004 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) LOW GAS PRESSURE 2) PEX LINES 12" FROM LIGHT CANS KITCHEN CEILING 3) AT KITCHEN SINKD PUT COLD WATER ON RIGHT SIDE 4) ISOLATE CU. WATER FROM DRYER DUCT 5) BANG PLATES GARAGE WALL TO HOUSE 6) SUPPORT 3/4" GAS LINE DINNING CEILING 7) TIGHEN ALL H.D. NUTS 8) TURN ON POTABLE WATER 9) NO WATER IN DWV 10) TUB BACKING FRONT BATH 11) NO PLANS/PERMIT ON SITE | |
03/15/2004 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) FIRESTOP CHASE BY FUR AT FUR DOWN 2) NO WATER TEST ON TOP OUT 3) WATER HEATER AND FURNACE SHALL BE ELECTRIC-NO B-VENTS 2) STUCCO MESH INSP REQUIRED PRIOR TO FRAME INSP |