Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
12/27/2004 BUILDING - FINAL Approved IVRS - Inspection :*
12/16/2004 BUILDING - FINAL Partial Approval IVRS - Inspection :*
1) CLEAN OUTS REQUIRE THREADED CAPS
2) OUTSIDE HOSE BIBS REQUIRE ANTI-SIPHON VALVES
3) GUEST HOUSE STAIR RUN AND RISE, DO NOT COMPLY WITH IRC 314.2
4) GUEST HOUSE STAIR RAIL NOT IN
5) STOOP REQUIRED AT EXIT DOORS. DOOR WIDTH BY 36" DEEP
6) KITCHEN GUEST HOUSE REQUIRES 2-20 AMP GFCI CIRCUITS
7) T & P ? MUST EXHAUST DOWN